Skip to main content
Schneider Electric ATV1200A88406060 — AC Drive (VFD) 480V

Schneider Electric ATV1200A88406060 AC Drive (VFD) 480V

MPNATV1200A88406060
Active

Schneider Electric Altivar 1200 ATV1200A88406060 AC Drive (VFD) 480V, 7390 kW, 2970-3630 V supply, 30-pulse diode rectifier, floor-standing enclosure.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV1200A88406060 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV1200
Product range / familyAltivar 1200

Power & Output

ATV1200A88406060 — Power & Output
ParameterValue
Motor power (kW)7390 kW
Continuous output current850 A (standard overload) 680 A (high overload)
Max. transient current1020 A for 60 s
Apparent power8840 kVA

Input / Supply

ATV1200A88406060 — Input / Supply
ParameterValue
Rated supply voltage range6 kV +/- 10 %
Input line current850 A
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)

Control & Performance

ATV1200A88406060 — Control & Performance
ParameterValue
Output frequency range0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback
Asynchronous motor control modesVoltage/frequency ratio (V/f) Vector control with sensor, optional Closed-loop control with encoder Sensorless flux vector control
Synchronous motor control modesVoltage/frequency ratio (V/f) Closed-loop control with encoder

Protection & EMC

ATV1200A88406060 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated
Protection functionsGround fault protection: drive
Prospective short-circuit current (Isc)31.5 kA for 150 ms

Mechanical & Cooling

ATV1200A88406060 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP41 IP42 IP31
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure with separate air flows

Environmental

ATV1200A88406060 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)
Operating altitude1000...2000 m with current derating 0.6 % per 100 m
Relative humidity0...90 % 0...95 % optional
Storage / transport temperature-10...60 °C
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance4.9 m/s² (f= 10...50 Hz)

Approvals

ATV1200A88406060 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1

Communication

ATV1200A88406060 — Communication
ParameterValue
Communication protocolsHuman machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9

Product details

Drive architecture and power stage

The ATV1200A88406060 is a medium-voltage AC drive rated for 7390 kW motor power, supplied from a 2970–3630 V input rail through a 30-pulse diode rectifier bridge. The 30-pulse topology cancels low-order harmonics at the input, reducing the need for external harmonic filtering on the line side. The drive is assembled in a floor-standing enclosure with separate air flows for the power cells and the phase-shifting transformer. Internal composition includes 15 power cells, medium-voltage arrestors, cooling fans, and a human-machine interface. Apparent power rating is 8840 kVA; line current is 850 A. Prospective short-circuit current withstand is 31.5 kA for 150 ms, which sets the fault-clearing requirement for the upstream protection.

Overload capability and protection

Standard overload profile: 1.2 × In for 60 s or 1.5 × In for 3 s. High overload profile: 1.5 × In for 60 s or 1.85 × In for 3 s. The drive includes integrated ground-fault protection and electrical isolation between power and control circuits. Dielectric strength between earth and power terminals is 20 kV AC. Overvoltage category II per EN/IEC 61800-5-1, pollution degree 2.

Physical footprint and installation constraints

Dimensions: 3040 mm high × 8970 mm wide × 1700 mm deep. The enclosure is grey (RAL 7032) and must be installed vertically within ±10° of true vertical. Cooling is forced convection with 90,000 m³/h airflow. Noise level is 80 dB. Ambient relative humidity range is 0–90 % (0–95 % optional). Electrical connection uses M10 bar-type screw terminals with clamping capacity for 6 × 40 mm² conductors, entry from bottom or top. An integrated EMC filter is included.

Frequently asked questions

What compliance documentation does Schneider Electric provide for ATV1200A88406060?

The drive carries CE marking and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Electrical isolation between power and control is standard.

MPN
ATV1200A88406060