Skip to main content
Schneider Electric ATV212HD75N4LCD — AC Drive (VFD) 480V

Schneider ATV212HD75N4LCD AC Drive, 75 kW, 100 hp, 480 V

MPNATV212HD75N4LCD
Obsolete

Schneider Electric Altivar 212 ATV212HD75N4LCD AC drive, 75 kW / 100 hp, 480 V, 320 x 630 x 290 mm, IP20, with integrated EMC filter.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

ATV212HD75N4LCD — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV212
Product range / familyAltivar 212
ATV212HD75N4LCD — Power & Output
ParameterValue
Motor power (kW)75 kW
Continuous output current160 A at 380 V 160 A at 460 V
Max. transient current176 A for 60 s
Apparent power105.3 kVA at 380 V
ATV212HD75N4LCD — Input / Supply
ParameterValue
Rated supply voltage range380...480 V - 15...10 %
Input line current141.8 A at 380 V 111.3 A at 480 V
Network number of phases3 phases
ATV212HD75N4LCD — Control & Performance
ParameterValue
Output frequency range0.5...200 Hz
Asynchronous motor control modesVoltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) Voltage/frequency ratio - Energy Saving, quadratic U/f Voltage/frequency ratio, 5 points Voltage/frequency ratio, 2 points Flux vector control without sensor, standard
ATV212HD75N4LCD — Protection & EMC
ParameterValue
Integrated EMC filter classClass C2 EMC filter integrated
Protection functionsOverheating protection: drive Thermal power stage: drive Short-circuit between motor phases: drive Input phase breaks: drive Overcurrent between output phases and earth: drive Overvoltages on the DC bus: drive Break on the control circuit: drive Against exceeding limit speed: drive Line supply overvoltage and undervoltage: drive Line supply undervoltage: drive Against input phase loss: drive Thermal protection: motor Motor phase break: motor With PTC probes: motor
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Prospective short-circuit current (Isc)22 kA
ATV212HD75N4LCD — Mechanical & Cooling
ParameterValue
IP degree of protectionIP20 on upper part without blanking plate on cover conforming to EN/IEC 61800-5-1 IP20 on upper part without blanking plate on cover conforming to EN/IEC 60529 IP21 conforming to EN/IEC 61800-5-1 IP21 conforming to EN/IEC 60529 IP41 on upper part conforming to EN/IEC 61800-5-1 IP41 on upper part conforming to EN/IEC 60529
Acoustic noise level63.7 dB conforming to 86/188/EEC
Assembly / installation styleWith heat sink
ATV212HD75N4LCD — Environmental
ParameterValue
Operating ambient temperature-10...40 °C (without derating) 40...50 °C (with derating factor)
Operating altitude1000...3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m <= 1000 m without derating
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3 5...95 % without dripping water conforming to IEC 60068-2-3
Storage / transport temperature-25...70 °C
Pollution degree3 conforming to IEC 61800-5-1
Vibration resistance1.5 mm (f= 3...13 Hz) conforming to EN/IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to EN/IEC 60068-2-8
ATV212HD75N4LCD — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN 61800-3 environments 1 category C2 EN 61800-3 environments 2 category C3 EN 61800-3 category C2 IEC 61800-3 category C3 IEC 61800-3 environments 1 category C2 IEC 61800-3 environments 1 category C1 IEC 61800-3 category C2 EN 61800-5-1 EN 61800-3 environments 2 category C1 IEC 61800-3 environments 2 category C3 UL Type 1 EN 61800-3 category C3 EN 61800-3 environments 1 category C3 EN 61800-3 IEC 61800-3 environments 2 category C1 IEC 61800-3 environments 2 category C2 IEC 61800-5-1 EN 55011 class A group 1 IEC 61800-3 environments 1 category C3 IEC 61800-3 EN 61800-3 environments 1 category C1 EN 61800-3 environments 2 category C2
ATV212HD75N4LCD — Communication
ParameterValue
Communication protocolsBACnet METASYS N2 APOGEE FLN Modbus LonWorks

Product details

75 kW at 480 V — motor power and line-side draw

The ATV212HD75N4LCD is a 75 kW / 100 hp Altivar 212 AC drive for asynchronous motors, rated for a 380–480 V supply. Line current at 480 V is 111.3 A; at 380 V it draws 141.8 A, with an apparent power of 105.3 kVA at the lower voltage. This is the drive for a 100 hp pump, fan, or conveyor — the Altivar 212 series is positioned as a mid-functionality, cost-optimised VFD for building services and light industrial duty.

Panel fit — 320 x 630 x 290 mm with 666 m³/h airflow

The drive measures 320 mm wide, 630 mm high, and 290 mm deep — a substantial footprint that demands a back-panel or floor-standing enclosure. The integrated fan moves 666 m³/h of air through the heatsink, so the enclosure must allow free intake and exhaust; the operating position is vertical ±10°. Altitude derating applies above 1000 m: 1 % per 100 m up to 3000 m, with a 2000 m limit for corner-grounded distribution networks.

Protection coverage and compliance envelope

The drive includes integrated Class C2 EMC filtering and meets EN/IEC 61800-3 environments 1 and 2 categories C1 through C3, plus EN 55011 Class A Group 1. Protection covers input phase loss, DC bus overvoltage/undervoltage, motor phase break, short-circuit between motor phases, overcurrent to earth, and PTC probe monitoring.

For a 100 hp VFD that is still in mature production, the supply posture is straightforward: submit an RFQ with your quantity and target delivery window.

Frequently asked questions

What compliance standards does the ATV212HD75N4LCD meet?

It carries CE marking and complies with EN/IEC 61800-3 for EMC in environments 1 and 2 categories C1 through C3, plus EN 55011 Class A Group 1. An integrated Class C2 EMC filter is standard.

What is the closest alternative to the ATV212HD75N4LCD in the Altivar family?

The Altivar 630 or 930 series would be the functional successors for new designs, but they require a different panel layout and parameter set. For existing BOMs, the ATV212HD75N4LCD remains the correct order code.

MPN