Schneider Electric ATV212WD15N4 — AC Drive (VFD) 480V

Schneider ATV212WD15N4 AC Drive (VFD) 480V, 15 kW, 3-phase

MPNATV212WD15N4
Active

Schneider Electric Altivar 212 ATV212WD15N4 AC drive, 15 kW, 3-phase 480 V, 22.6 A line current, integrated Class C2 EMC filter, CE/UL/CSA.

$1,564.64 – $3,454.67Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATV212WD15N4 — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV212
Product range / familyAltivar 212
ATV212WD15N4 — Power & Output
ParameterValue
Motor power (kW)15 kW
Continuous output current30.5 A 380 V 30.5 A 460 V
Max. transient current33.6 A 60 s
Apparent power23.2 kVA 380 V
ATV212WD15N4 — Input / Supply
ParameterValue
Rated supply voltage range380...480 V - 15...10 %
Input line current22.6 A 480 V 28.4 A 380 V
ATV212WD15N4 — Control & Performance
ParameterValue
Output frequency range0.5...200 Hz
Asynchronous motor control modesVoltage/frequency ratio - Energy Saving, quadratic U/f Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) Voltage/frequency ratio, 2 points Flux vector control without sensor, standard Voltage/frequency ratio, 5 points
ATV212WD15N4 — Protection & EMC
ParameterValue
Integrated EMC filter classClass C2 EMC filter integrated
Protection functionsOverheating protection drive Thermal power stage drive Short-circuit between motor phases drive Input phase breaks drive Overcurrent between output phases and earth drive Overvoltages on the DC bus drive Break on the control circuit drive Against exceeding limit speed drive Line supply overvoltage and undervoltage drive Line supply undervoltage drive Against input phase loss drive Thermal protection motor Motor phase break motor With PTC probes motor
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Prospective short-circuit current (Isc)22 kA
ATV212WD15N4 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP55
Acoustic noise level57.4 dB 86/188/EEC
Assembly / installation styleWith heat sink
ATV212WD15N4 — Environmental
ParameterValue
Operating ambient temperature14...104 °F (-10...40 °C) (without derating) 104...122 °F (40...50 °C) (with derating factor)
Operating altitude3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m <= 3280.84 ft (1000 m) without derating
Relative humidity5...95 % without condensation IEC 60068-2-3 5...95 % without dripping water IEC 60068-2-3
Storage / transport temperature-13...158 °F (-25...70 °C)
Pollution degree2 IEC 61800-5-1
Vibration resistance1.5 mm (f= 3...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to EN/IEC 60068-2-8
ATV212WD15N4 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceIEC 61800-5-1 IEC 61800-3 environments 1 category C1 IEC 61800-3 environments 1 category C2 IEC 61800-3 environments 1 category C3 IEC 61800-3 environments 2 category C1 IEC 61800-3 environments 2 category C2 IEC 61800-3 environments 2 category C3 CE UL CSA C-Tick N1831 GOST
ATV212WD15N4 — Communication
ParameterValue
Communication protocolsModbus METASYS N2 BACnet LonWorks APOGEE FLN

Product details

What this drive delivers on a 480 V line

The ATV212WD15N4 is an Altivar 212 AC drive rated for 15 kW output on a 3-phase 480 V supply — sized for asynchronous motors in pump, fan, and conveyor duty where the load profile stays within the drive's constant-torque curve. Line current at 480 V is 22.6 A; at 380 V it draws 28.4 A, so the upstream protection and cable sizing follow the higher figure when the supply is on the low side of the tolerance band.

Regulatory and installation fit

The integrated Class C2 EMC filter covers most industrial power-distribution layouts without an external filter. Pollution degree 2 per IEC 61800-5-1 and a 15 gn / 11 ms shock rating per IEC 60068-2-27 mean it handles the vibration and contamination levels typical of a panel-mounted drive near a motor or gearbox.

Lifecycle and sourcing posture

The lifecycle stage is marked as mature — this is not a new-introduction or end-of-life flag, but it means the drive has been in the field long enough that spares and replacements are stable through distribution. No official successor order code is recorded.

Protection and control depth

Built-in protections cover overheating, short-circuit between motor phases, input phase loss, overcurrent between output phases and earth, DC-bus overvoltage, and motor thermal protection with PTC probe support — the drive can shut down on a winding overtemperature without an external relay. An adjustable PI regulator is onboard for closed-loop process control — pressure, flow, or level loops can be tuned directly in the drive without a separate controller. The analogue input stage is switch-configurable between voltage (0–10 V DC) and current (0–20 mA) with 10-bit resolution, and one input can serve as a PTC probe interface for motor temperature feedback.

Frequently asked questions

How do I get pricing and availability for the ATV212WD15N4?

We source this drive to order against the BOM quantity.

What compliance documentation does Schneider provide for this drive?

The ATV212WD15N4 carries CE, UL, CSA, and C-Tick markings and meets IEC 61800-5-1 (safety) and IEC 61800-3 (EMC) for environments 1 and 2 up to category C3. The integrated Class C2 EMC filter is listed.

MPN