Skip to main content
Schneider Electric ATV212WU22N4CZH28 — AC Drive (VFD) 480V

Schneider ATV212WU22N4CZH28 Altivar 212 VFD, 2.2 kW, C1 EMC

MPNATV212WU22N4CZH28
Obsolete

Schneider Electric Altivar 212 series, ATV212WU22N4CZH28, variable speed drive for asynchronous motors, 2.2 kW / 3 hp, 380…480 V three-phase, integrated Class C1 EMC filter, CE marked.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

ATV212WU22N4CZH28 — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV212
Product range / familyAltivar 212
ATV212WU22N4CZH28 — Power & Output
ParameterValue
Motor power (kW)2.2 kW
Continuous output current5.1 A at 380 V 5.1 A at 460 V
Max. transient current5.6 A for 60 s
Apparent power3.9 kVA at 380 V
ATV212WU22N4CZH28 — Input / Supply
ParameterValue
Rated supply voltage range380...480 V - 15...10 %
Input line current4.6 A at 380 V 3.7 A at 480 V
Network number of phases3 phases
ATV212WU22N4CZH28 — Control & Performance
ParameterValue
Output frequency range0.5...200 Hz
Asynchronous motor control modesFlux vector control without sensor, standard Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) Voltage/frequency ratio - Energy Saving, quadratic U/f Voltage/frequency ratio, 5 points Voltage/frequency ratio, 2 points
ATV212WU22N4CZH28 — Protection & EMC
ParameterValue
Integrated EMC filter classClass C1 EMC filter integrated
Protection functionsOverheating protection: drive Thermal power stage: drive Short-circuit between motor phases: drive Input phase breaks: drive Overcurrent between output phases and earth: drive Overvoltages on the DC bus: drive Break on the control circuit: drive Against exceeding limit speed: drive Line supply overvoltage and undervoltage: drive Line supply undervoltage: drive Against input phase loss: drive Thermal protection: motor Motor phase break: motor With PTC probes: motor
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Prospective short-circuit current (Isc)5 kA
ATV212WU22N4CZH28 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP54 conforming to EN/IEC 61800-5-1 IP54 conforming to EN/IEC 60529
Acoustic noise level48 dB conforming to 86/188/EEC
Assembly / installation styleWith heat sink
ATV212WU22N4CZH28 — Environmental
ParameterValue
Operating ambient temperature-10...40 °C (without derating) 40...50 °C (with derating factor)
Operating altitude1000...3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m <= 1000 m without derating
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3 5...95 % without dripping water conforming to IEC 60068-2-3
Storage / transport temperature-25...70 °C
Pollution degree3 conforming to IEC 61800-5-1
Vibration resistance1.5 mm (f= 3...13 Hz) conforming to EN/IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to EN/IEC 60068-2-8
ATV212WU22N4CZH28 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN 61800-3 environments 1 category C3 IEC 61800-3 environments 2 category C3 EN 61800-3 environments 2 category C1 IEC 61800-5-1 EN 61800-3 environments 2 category C2 IEC 61800-3 environments 2 category C2 EN 61800-5-1 IEC 61800-3 category C1 IEC 61800-3 environments 1 category C1 IEC 61800-3 environments 2 category C1 EN 61800-3 environments 1 category C2 EN 61800-3 environments 2 category C3 IEC 61800-3 environments 1 category C3 EN 61800-3 IEC 61800-3 environments 1 category C2 IEC 61800-3 EN 55011 group 1 class B EN 61800-3 environments 1 category C1 EN 61800-3 category C1
ATV212WU22N4CZH28 — Communication
ParameterValue
Communication protocolsMETASYS N2 APOGEE FLN Modbus BACnet LonWorks

Product details

The ATV212WU22N4CZH28 is a Schneider Altivar 212 variable speed drive rated for 2.2 kW / 3 hp asynchronous motor loads on a 380…480 V three-phase supply. Line current draws 4.6 A at 380 V and 3.7 A at 480 V, with apparent power of 3.9 kVA at 380 V. The integrated Class C1 EMC filter covers EN 61800-3 environments 1 and 2 categories C1 through C3, so it meets residential and industrial emission limits without an external filter — saves a DIN-rail slot and a wiring step. Switching frequency is adjustable from 6 to 16 kHz; above 12 kHz you derate the output current. Speed range runs 1 to 10 with ±10 % slip compensation from 0.2 Tn to Tn. Torque accuracy sits at ±15 %. The drive includes an adjustable PI regulator for closed-loop process control — pump, fan, conveyor applications where you want a setpoint, not just open-loop speed.

Dimensions are 215 mm wide, 297 mm tall, 192 mm deep — that depth (192 mm) is the key number for enclosure depth clearance; a standard 300 mm deep panel leaves you about 100 mm behind the door for wiring and finger clearance. Assembly style is with a heat sink, so it needs free air circulation around the fins. Operating position is vertical ±10°, pollution degree 3 per IEC 61800-5-1. Relative humidity range 5…95 % non-condensing. Altitude derating starts above 1000 m; corner-grounded distribution networks are limited to 2000 m.

Communications and I/O

Physical interface is 2-wire RS-485 with Modbus RTU frame at 9600 or 19200 bps, 8 bits, 1 stop, parity configurable. Supports up to 247 addresses on the bus. An optional LonWorks communication card is available. Analog inputs are switch-configurable for voltage (0…10 V DC, 30 kΩ impedance) or current (0…20 mA, 250 Ω), 10-bit resolution. One input also accepts PTC probes for motor thermal protection.

Frequently asked questions

What is the depth of ATV212WU22N4CZH28?

The depth is 192 mm. That is the dimension from the mounting surface to the front of the drive — critical for enclosure depth planning.

What compliance documentation does ATV212WU22N4CZH28 carry?

CE marked per EN 61800-3 and EN 61800-5-1. The integrated C1 EMC filter covers all EN 61800-3 environment categories for both environment 1 and 2. Also complies with EN 55011 Group 1 Class B. Pollution degree 3 per IEC 61800-5-1.

Where can I buy ATV212WU22N4CZH28?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm position.

MPN