Skip to main content
Schneider Electric ATV6A0C25T4 — AC Drive (VFD) 480V

ATV6A0C25T4 Altivar Process ATV600 250 kW Drive, STO SIL3

MPNATV6A0C25T4
Active

Schneider Electric Altivar Process ATV600, modular drive, ATV6A0C25T4, 250 kW / 400 hp normal duty, 355 kVA at 480 V, STO SIL3, integrated EMC C3.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV6A0C25T4 — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV6A0
Product range / familyAltivar Process ATV600

Power & Output

ATV6A0C25T4 — Power & Output
ParameterValue
Motor power (kW)250.0 kW at 480 V normal duty 200.0 kW at 480 V heavy duty
Continuous output current477.0 A at 2.5 kHz normal duty 370.0 A at 2.5 kHz heavy duty
Max. transient current524.7 A 60 s normal duty) 555 A 60 s heavy duty)
Apparent power355 kVA at 480 V normal duty 273 kVA at 480 V heavy duty

Input / Supply

ATV6A0C25T4 — Input / Supply
ParameterValue
Rated supply voltage range480 V - 15...10 %
Input line current427.0 A 480 V normal duty) 328.0 A 480 V heavy duty)
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), <200 mA overload and short-circuit protection

Control & Performance

ATV6A0C25T4 — Control & Performance
ParameterValue
Output frequency range0...500 Hz
Asynchronous motor control modesConstant torque standard Variable torque standard Optimized torque mode
Synchronous motor control modesPermanent magnet motor

Protection & EMC

ATV6A0C25T4 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated 984.3 ft (300 m) IEC 61800-3 category C3
Protection functionsThermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)50 kA

Mechanical & Cooling

ATV6A0C25T4 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529
Acoustic noise level70 dB 86/188/EEC
Cooling methodForced convection

Environmental

ATV6A0C25T4 — Environmental
ParameterValue
Operating ambient temperature14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor
Operating altitude1000...4800 m with current derating 1 % per 100 m
Relative humidity5...95 % without condensation IEC 60068-2-3
Storage / transport temperature-40...158 °F (-40...70 °C)
Pollution degree2 IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6

Approvals

ATV6A0C25T4 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1

Communication

ATV6A0C25T4 — Communication
ParameterValue
Communication protocolsEthernet Modbus serial Modbus TCP

Product details

The Schneider Electric ATV6A0C25T4 is a modular Altivar Process ATV600 drive rated for 250 kW at 480 V normal duty (400 hp) with an apparent power of 355 kVA and line current of 427 A under normal duty. Heavy-duty rating steps down to 200 kW / 300 hp with 273 kVA and 328 A. That split matters: normal duty covers centrifugal pumps and fans; heavy duty handles conveyors or extruders where overload margin is tighter. The integrated EMC filter meets IEC 61800-3 category C3, which is the standard for industrial environments with conducted emissions limits up to 300 m of motor cable. No external filter needed for most installations inside a factory shed, but verify local network impedance if the drive feeds a shared transformer.

Safe torque off is built in at SIL3 (IEC 61508 / IEC 13849-1). That means two independent channels to disable torque; the drive supports both STOA and STOB 24 V DC inputs with 2.2 kOhm impedance. No separate safety relay card required for single-axis STO — the control unit handles it directly. The control supply splits into three rails: 24 V DC for digital inputs (19...30 V), 10.5 V DC for a reference potentiometer (1 to 10 kOhm), and a separate 24 V DC supply for STO. All three are protected against overload and short circuit to 200 mA.

Compliance paperwork is standard: CE marking, IEC 61800-3, -5-1, -61000-3-12, -60721-3, plus functional safety standards IEC 61508 and IEC 13849-1. The integrated EMC filter is already C3 rated. No separate certification delays for most machine builds.

Frequently asked questions

What compliance standards does this drive meet?

CE marking, IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. The EMC filter is integrated to category C3.

MPN
ATV6A0C25T4