Schneider Electric C080L42AFM — Miniature Circuit Breakers (MCB)

Schneider Electric C080L42AFM ComPacT NS 800A 4P MCCB, 150 k

MPNC080L42AFM
Active

Schneider Electric ComPacT NS new generation, C080L42AFM, 800 A at 50 °C, 4 poles, MicroLogic 2.0 A electronic trip unit, 150 kA Icu at 415 V AC, fixed mount, IP40.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C080L42AFM — Identification
ParameterValue
Product nameComPacT NS new generation
Product rangeComPacT
Product range (series)ComPacT NS630b...1600 new generation
Product/component typeCircuit breaker
Device applicationDistribution
C080L42AFM — Ratings
ParameterValue
Rated current (In)800 A at 50 °C
Breaking capacity150 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 150 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 130 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)150 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 150 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 130 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)8 kV conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C080L42AFM — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)2000 cycles at 690 V In 3000 cycles at 690 V In/2 3000 cycles at 440 V In 4000 cycles at 440 V In/2
Mechanical durability (cycles)10000 cycles
C080L42AFM — Mechanical
ParameterValue
Mounting supportBackplate
Mounting modeFixed
Control typeManually operated
Local signalling/indication4 LEDs (red) for fault indication 1 LED (yellow) for overload
C080L42AFM — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947
Relative humidity0...95 %
C080L42AFM — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C080L42AFM — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.4...1 x In
Trip unit protection functionsLI

Product details

What this MCCB delivers

The Schneider Electric C080L42AFM is a ComPacT NS new generation moulded-case circuit breaker (MCCB) rated 800 A at 50 °C, with 4 poles and a MicroLogic 2.0 A electronic trip unit providing L (long-time overload) and I (instantaneous short-circuit) protection per EN/IEC 60947-2.

The electronic MicroLogic 2.0 A trip unit gives you adjustable long-time and instantaneous pickup settings, not a fixed thermal curve. Breaking capacity is 150 kA Icu at 220/240 V and 380/415 V AC, 130 kA at 440 V, and 100 kA at 500/525 V AC — all at 50/60 Hz. For a 480 V distribution panel (common in North America), the 100 kA at 500/525 V rating is the relevant figure; verify your available fault current against that. Mechanical durability is 10,000 cycles; electrical durability varies by load — 2,000 cycles at 690 V In, 3,000 at 690 V In/2, 3,000 at 440 V In, and 4,000 at 440 V In/2. That's typical for a fixed-mount distribution breaker not used for frequent switching.

Fixed mounting on a backplate (not DIN rail), with front-connect terminals top and bottom. The 280 mm width, 327 mm height, and 147 mm depth determine the panel cutout and enclosure size — plan for that footprint plus bending space for 800 A cables. IP40 enclosure protection means it's suited for indoor panel installation where no water jets or dust ingress are expected. IK07 impact resistance covers light mechanical shock during handling. Power losses are 20 W at rated current — account for that heat in the enclosure thermal calculation, especially if multiple breakers are ganged.

Frequently asked questions

What is the breaking capacity of C080L42AFM at 415 V?

150 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2. At 440 V it's 130 kA; at 500/525 V it's 100 kA.

What trip unit does C080L42AFM use?

A MicroLogic 2.0 A electronic trip unit with L (long-time overload) and I (instantaneous short-circuit) protection. It includes an ammeter and LCD display for local reading.