Skip to main content
Schneider Electric C080L45AFM — Miniature Circuit Breakers (MCB)

Schneider Electric C080L45AFM ComPacT NS 800A 4P MCCB, 150kA

MPNC080L45AFM
Obsolete

Schneider Electric ComPacT NS new generation, C080L45AFM, 4-pole MCCB, 800 A at 50 °C, MicroLogic 5.0 A trip unit, 150 kA Icu at 415 V AC, fixed mount, IP40.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C080L45AFM — Identification
ParameterValue
Product nameComPacT NS new generation
Product rangeComPacT
Product range (series)ComPacT NS630b...1600 new generation
Product/component typeCircuit breaker
Device applicationDistribution
C080L45AFM — Ratings
ParameterValue
Rated current (In)800 A at 50 °C
Breaking capacity150 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 150 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 130 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)150 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 150 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 130 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)8 kV conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C080L45AFM — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)2000 cycles at 690 V In 3000 cycles at 690 V In/2 3000 cycles at 440 V In 4000 cycles at 440 V In/2
Mechanical durability (cycles)10000 cycles
C080L45AFM — Mechanical
ParameterValue
Mounting supportBackplate
Mounting modeFixed
Control typeManually operated
Local signalling/indication4 LEDs (red) for fault indication 1 LED (yellow) for overload
C080L45AFM — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947
Relative humidity0...95 %
C080L45AFM — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C080L45AFM — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.4...1 x In
Trip unit protection functionsLSI

Product details

MCCB for distribution panels — 800 A, 4P, MicroLogic 5.0 A

The Schneider Electric C080L45AFM is a ComPacT NS new generation 4-pole molded-case circuit breaker rated 800 A at 50 °C, fitted with a MicroLogic 5.0 A electronic trip unit. It provides overload (L), short-time short-circuit (S), and instantaneous short-circuit (I) protection, making it suitable for distribution applications in industrial and commercial power panels. The breaker is manually operated with an LCD display for local metering and fault indication via four red LEDs and one yellow LED for overload.

Rated 150 kA Icu at 415 V AC 50/60 Hz per IEC 60947-2, this MCCB handles high fault currents typical of transformer-fed switchboards. The 130 kA Icu at 440 V and 100 kA at 500/525 V give headroom for systems with higher nominal voltages. The MicroLogic 5.0 A trip unit's short-time (S) setting allows selectivity with downstream breakers — critical for coordinating a distribution panel so a fault on a branch does not take the main breaker out.

Fixed-mount design for backplate installation. Connection pitch is 70 mm; both upside and downside connections are front-accessible. Dimensions: 327 mm high, 280 mm wide, 147 mm deep. Neutral is on the left. The breaker is rated for 20 W power losses and includes thermal memory of 20 minutes. Mechanical durability is 10,000 cycles; electrical durability varies by voltage and load — 2,000 cycles at 690 V In, 3,000 cycles at 690 V In/2, 3,000 cycles at 440 V In, 4,000 cycles at 440 V In/2.

Frequently asked questions

Where can I buy C080L45AFM and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the breaking capacity of C080L45AFM?

150 kA Icu at 415 V AC 50/60 Hz per IEC 60947-2, with 130 kA at 440 V and 100 kA at 500/525 V.

What trip unit does C080L45AFM use?

It uses a MicroLogic 5.0 A electronic trip unit with L, S, and I protection curves.

What compliance documentation is available for C080L45AFM?

Schneider Electric provides RoHS, REACH, UL, and IEC compliance documentation with the unit.

MPN
C080L45AFM