Skip to main content
Schneider Electric C100H460FM

Schneider Electric C100H460FM ComPacT NS 1000A, 85 kA Icu

MPN C100H460FM
Active

Schneider Electric ComPacT NS new generation, C100H460FM, manually operated 4P circuit breaker, 1000 A trip unit rating, MicroLogic 6.0 electronic trip unit, 85 kA Icu at 240 V AC, EN/IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C100H460FM key specifications
ParameterValue
Control typeManually operated
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Poles4P
Utilization categoryCategory B
IP ratingIP40
Terminal pitch70 mm
Connection surface topFront
Connection surface bottomFront

All specifications

C100H460FM additional specifications
ParameterValue
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degree3 conforming to IEC 60947
Depth147 mm
Width280 mm
Height327 mm
Electrical life cycles2000 cycles at 690 V In 4000 cycles at 690 V In/2 5000 cycles at 440 V In 6000 cycles at 440 V In/2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The C100H460FM is a Schneider Electric ComPacT NS new generation manually operated circuit breaker, 4 poles, with a 1000 A MicroLogic 6.0 electronic trip unit. It's built for distribution duty in switchboards and panelboards, rated per EN/IEC 60947-2.

Mounts fixed to a backplate — no DIN rail here. The 327 mm height, 280 mm width, and 147 mm depth mean it needs a substantial cutout in the gland plate; plan for the 70 mm connection pitch when laying out bus bars or cable lugs. IP40 enclosure protection keeps out tools and fingers but isn't rated for washdown — install it in a dry, indoor switchboard. Front connections top and bottom simplify bus routing in a lineup. The MicroLogic 6.0 is fully electronic, so no thermal bimetal to drift; the 20-minute thermal memory matches the cooling curve of conductors after a fault.

Mechanical durability is 10,000 cycles — that's the maintenance interval to track. The four red LEDs give fault indication (overload, short circuit, ground fault, etc.) and a yellow LED signals an overload alarm — useful for a technician walking the lineup. Overvoltage category III suits fixed-installation distribution boards.

MPN