Schneider Electric C100L350FM — Miniature Circuit Breakers (MCB)

Schneider Electric C100L350FM ComPacT NS, 1000A, 150kA 415V

MPNC100L350FM
Active

Schneider Electric ComPacT NS new generation, C100L350FM, 3P fixed circuit breaker, 1000 A at 50 °C, MicroLogic 5.0 electronic trip unit, 150 kA Icu at 415 V AC, manually operated.

$6,530.71Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C100L350FM — Identification
ParameterValue
Product nameComPacT NS new generation
Product rangeComPacT
Product range (series)ComPacT NS630b...1600 new generation
Product/component typeCircuit breaker
Device applicationDistribution
C100L350FM — Ratings
ParameterValue
Rated current (In)1000 A at 50 °C
Breaking capacity150 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 150 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 130 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)150 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 150 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 130 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)8 kV conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C100L350FM — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)2000 cycles at 690 V In 3000 cycles at 690 V In/2 3000 cycles at 440 V In 4000 cycles at 440 V In/2
Mechanical durability (cycles)10000 cycles
C100L350FM — Mechanical
ParameterValue
Mounting supportBackplate
Mounting modeFixed
Control typeManually operated
Local signalling/indication4 LEDs (red) for fault indication 1 LED (yellow) for overload
C100L350FM — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947
Relative humidity0...95 %
C100L350FM — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C100L350FM — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.4...1 x In
Trip unit protection functionsLSI

Product details

What this breaker brings to a 1000 A distribution bus

The Schneider Electric C100L350FM is a 3-pole fixed-mount ComPacT NS new generation circuit breaker rated 1000 A at 50 °C with a MicroLogic 5.0 electronic trip unit. The electronic trip unit lets you dial in the curves on site rather than swapping thermal elements, which matters when you are commissioning a distribution board and need to adjust selectivity with the feeder breakers below it.

The C100L350FM carries 150 kA Icu at 220/240 V AC and at 380/415 V AC, then steps down to 130 kA at 440 V AC and 100 kA at 500/525 V AC. The 100 kA at 525 V still covers most 480 V industrial systems in North America, though the primary standard here is IEC 60947-2.

Lifecycle and sourcing — still in current production

Fixed-mount on a backplate, 327 mm high by 210 mm wide by 147 mm deep. Front-connect on both line and load sides — no rear-access requirement, which simplifies gland-plate layout in a standard IP40 enclosure. Power loss is 34 W at rated current. That is not trivial for a sealed panel — if you are packing multiple 1000 A breakers in a single enclosure, factor that heat into the ventilation or cooling budget. The thermal memory of 20 minutes means the trip curve remembers prior heating after a temporary overload, so it does not reset instantly and risk nuisance tripping on a re-energised warm bus.

Durability and signalling

Mechanical durability of 10,000 cycles and electrical durability of 2,000 cycles at rated current and voltage (690 V In). That is typical for a fixed-mount distribution breaker — it is not designed for daily switching like a contactor, but it handles the occasional load-break for maintenance isolation. Four red LEDs for fault indication and one yellow LED for overload give local diagnostics without opening the panel door.

Frequently asked questions

How do I get current pricing and availability for C100L350FM?

The C100L350FM is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote on your quantity and delivery window.

What is the breaking capacity of C100L350FM at 415 V?

It delivers 150 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2 — the full rated ultimate breaking capacity, not a one-shot withstand.

What trip unit does C100L350FM use?

It uses a MicroLogic 5.0 electronic trip unit with LSIG protection: long-time overload, short-time short-circuit, instantaneous short-circuit, and ground-fault (optional).

What compliance documentation does this brand provide for C100L350FM?

The breaker is certified to EN/IEC 60947-2, rated for isolation, pollution degree 3, overvoltage category III. Standard Schneider documentation includes the IEC declaration of conformity and test certificates for the breaking capacity values listed.