Schneider Electric C100L35AFM — Miniature Circuit Breakers (MCB)

Schneider Electric C100L35AFM ComPacT NS, 1000 A, 150 kA

MPNC100L35AFM
Active

Schneider Electric ComPacT NS new generation, C100L35AFM, 3P fixed MCCB, 1000 A, 150 kA Icu at 415 V AC, MicroLogic 5.0 A electronic trip unit, LSI protection, IP40, IK07.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C100L35AFM — Identification
ParameterValue
Product nameComPacT NS new generation
Product rangeComPacT
Product range (series)ComPacT NS630b...1600 new generation
Product/component typeCircuit breaker
Device applicationDistribution
C100L35AFM — Ratings
ParameterValue
Rated current (In)1000 A at 50 °C
Breaking capacity150 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 150 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 130 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)150 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 150 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 130 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)8 kV conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C100L35AFM — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)2000 cycles at 690 V In 3000 cycles at 690 V In/2 3000 cycles at 440 V In 4000 cycles at 440 V In/2
Mechanical durability (cycles)10000 cycles
C100L35AFM — Mechanical
ParameterValue
Mounting supportBackplate
Mounting modeFixed
Control typeManually operated
Local signalling/indication4 LEDs (red) for fault indication 1 LED (yellow) for overload
C100L35AFM — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947
Relative humidity0...95 %
C100L35AFM — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C100L35AFM — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.4...1 x In
Trip unit protection functionsLSI

Product details

The C100L35AFM is a 3-pole fixed-mount ComPacT NS new generation MCCB rated 1000 A at 50 °C. The breaking capacity is 150 kA Icu at 380/415 V AC, 50/60 Hz per IEC 60947-2. The MicroLogic 5.0 A electronic trip unit provides LSI protection: long-time overload (L), short-time short-circuit (S), and instantaneous short-circuit (I). The S protection (short-time) allows selectivity with downstream breakers — you can set a delay so the downstream device clears a fault first, keeping this breaker closed to supply other loads. Thermal memory of 20 minutes means the trip curve remembers prior heating, so repeated overloads accumulate correctly. This breaker is designed for distribution applications — main or feeder protection in switchboards, panelboards, or motor control centers. It is manually operated with an LCD display showing measured current (ammeter type,). The fixed-mount, backplate support means it bolts directly to a panel backplate, not a draw-out cradle — plan for 210 mm width, 327 mm height, 147 mm depth. Connection pitch is 70 mm, front-connect both upside and downside, so busbar or cable terminations are accessible from the front.

Mounts on a backplate in a fixed position — no DIN rail, no draw-out cradle. IK07 impact rating withstands a 2 J hammer blow — enough for accidental tool drops during maintenance. Operating altitude is 0–2000 m without derating, 2000–5000 m with derating. Relative humidity 0–95%. Power losses are 34 W at rated current — account for that in panel thermal calculations.

Durability and compliance

Mechanical durability is 10,000 cycles; electrical durability varies with load: 2000 cycles at 690 V at In, 3000 cycles at 690 V at In/2, 3000 cycles at 440 V at In, 4000 cycles at 440 V at In/2. That is typical for a distribution MCCB — not a switching device for frequent motor starts. Standards compliance is EN/IEC 60947-2 — the global standard for low-voltage circuit breakers. No earth-leakage protection built in; if ground-fault protection is needed, specify an external relay or a MicroLogic with Vigi module.

Frequently asked questions

Where can I buy C100L35AFM and get a price?

The C100L35AFM is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the closest alternative to C100L35AFM in the same family?

Within the ComPacT NS630b...1600 new generation range, the closest alternative would be a different trip-unit rating or breaking capacity variant — for example, a 800 A or 1250 A version with the same MicroLogic 5.0 A trip unit. The physical footprint (210 mm width, 327 mm height) is shared across the range, so a rating change does not affect panel cutout.

What compliance documentation does Schneider provide for C100L35AFM?

The C100L35AFM is certified to EN/IEC 60947-2. Standard documentation includes the IEC declaration of conformity, test reports for breaking capacity, and a product datasheet. RoHS and REACH compliance is standard for the ComPacT NS range, though specific declarations should be requested at order time.