Skip to main content
Schneider Electric C1034A040 — Residual Current Breakers (RCCB/RCBO)

C1034A040 ComPacT NSX MicroLogic 4.2 AL Trip Unit, 40 A, 3P

MPNC1034A040
Active

Schneider Electric ComPacT NSX100...250 series, MicroLogic 4.2 AL electronic trip unit, 40 A at 40 °C, 3-pole 3D, LSoI protection with integrated earth-leakage, EN/IEC 60947-2.

$10.42Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

C1034A040 — Residual Current Protection
ParameterValue
Earth-leakage protection class / typeClass A
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload Color indicator (yellow) for residual current
C1034A040 — Electrical Ratings
ParameterValue
Rated operational voltage (Ue)440 V AC 50/60 Hz
Poles description3P
Network typeAC
Network frequency50/60 Hz
C1034A040 — Identification
ParameterValue
Product / component typeTrip unit
Product range / familyComPacT
C1034A040 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-1
C1034A040 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

MicroLogic 4.2 AL trip unit for ComPacT NSX100...250

The Schneider Electric C1034A040 is a MicroLogic 4.2 AL electronic trip unit for the ComPacT NSX100...250 range of molded-case circuit breakers. It is a 3-pole (3D protected) unit rated at 40 A at 40 °C, with an operational voltage of 440 V AC at 50/60 Hz. The trip unit provides LSoI protection: long-time overload (L), short-time short-circuit with fixed delay (So), and instantaneous short-circuit (I), plus integrated earth-leakage protection (Class A).

Protection settings and adjustability

The long-time pickup Ir is adjustable across 9 settings from 18 to 40 A, with fixed delay curves: 400 s at 1.5 x Ir, 16 s at 6 x Ir, and 11 s at 7.2 x Ir. Short-time pickup Isd adjusts from 1.5 to 10 x Ir, with a fixed delay. Instantaneous pickup Ii is fixed at 600 A. Earth-leakage sensitivity IΔn and time delay Δt are both adjustable, with Δt selectable from 0 ms, 60 ms, 150 ms, 500 ms, or 1 s.

The trip unit is designed to EN/IEC 60947-2, with a pollution degree of 3 per IEC 60947-1 and IP40 front-face protection per IEC 60529. The unit is Class II for electrical shock protection.

This is a fixed-mount trip unit for the ComPacT NSX100...250 breaker frame. It occupies the standard 3-pole slot and communicates local status via a flashing green LED (ready), red LED at 105% Ir (overload), orange LED at 90% Ir (pre-alarm), and a yellow indicator for residual current. No zone selective interlocking (ZSI) is provided on this variant. The earth-leakage function can be disabled via the IΔn rotary switch for applications where ground-fault coordination is handled upstream.

Frequently asked questions

What are the key protection functions of C1034A040?

The MicroLogic 4.2 AL provides LSoI protection: long-time overload (L) with adjustable Ir 18-40 A, short-time short-circuit (So) with adjustable Isd 1.5-10 x Ir and fixed delay, instantaneous short-circuit (I) fixed at 600 A, and integrated earth-leakage protection (Class A) with adjustable IΔn and Δt.

What standards does C1034A040 comply with?

The trip unit complies with EN/IEC 60947-2, with pollution degree 3 per IEC 60947-1 and IP40 front protection per IEC 60529.

Where can I buy C1034A040 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN