Schneider Electric C10H34V100 — Residual Current Breakers (RCCB/RCBO)

C10H34V100 ComPacT NSX Earth Leakage Breaker, 100 A, 100 kA

MPNC10H34V100
Active

Schneider Electric ComPacT NSX, earth leakage circuit breaker, 3P, 100 A at 40 °C, MicroLogic 4.2 electronic trip unit, 100 kA Icu at 240 V AC, EN/IEC 60947-2.

$1,063.78 – $2,067.12Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C10H34V100 — Residual Current Protection
ParameterValue
Earth-leakage protection class / typeClass A
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C10H34V100 — Electrical Ratings
ParameterValue
Rated current (In)100 A at 40 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz
Poles description3P
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Overvoltage categoryIV
Electrical durability50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Mechanical durability (operating cycles)50000 cycles
C10H34V100 — Identification
ParameterValue
Product nameComPacT NSX
Product / component typeEarth leakage circuit breaker
Product range / familyComPacT
Device short nameNSX100H
C10H34V100 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical Flat on the back
Control typeToggle
C10H34V100 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C10H34V100 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The Schneider Electric C10H34V100 is a ComPacT NSX earth leakage circuit breaker (ELCB) with a MicroLogic 4.2 electronic trip unit, rated 100 A at 40 °C. It provides overload (L), short-time short-circuit (So), instantaneous short-circuit (I), and integrated earth-leakage (R) protection in a 3-pole, 105 mm wide package for backplate mounting. The H breaking capacity code delivers 70 kA Icu at 415 V AC per IEC 60947-2, and 100 kA Icu at 240 V AC — enough headroom for most distribution panel main or feeder positions without cascading upstream.

Above that, the electronic trip unit thermally models the conductor — the 20-minute thermal memory means it remembers prior heating even after a trip resets, so re-energizing a hot circuit won't nuisance-trip on the second start. Integrated earth-leakage protection (R function) means no external RCM or toroid is needed — the MicroLogic 4.2 handles ground-fault sensing internally. The OFF position is set via the IΔn rotary switch, which lets you select the residual sensitivity without opening the cover.

Deployment context

Backplate-mounted in a distribution panel with front-facing connections top and bottom.

Frequently asked questions

What is C10H34V100's breaking capacity at 415 V AC?

70 kA Icu at 415 V AC per IEC 60947-2, which is the H breaking capacity code. At 240 V AC it reaches 100 kA Icu.

What protection functions does the MicroLogic 4.2 trip unit provide?

Long-time overload (L), short-time short-circuit with fixed delay (So), instantaneous short-circuit (I), and integrated earth-leakage (R) protection.

Where can I buy C10H34V100 and how is it quoted?

It is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability.

MPN
C10H34V100