C10W46E040 ComPacT NSX 40A 4P MCCB, 100 kA Icu 690 V AC

MPNC10W46E040
Active

C10W46E040, Schneider Electric ComPacT NSX, 40 A, 4P, MicroLogic 6.2 E electronic trip unit, 100 kA Icu at 690 V AC, EN/IEC 60947-2.

$15.26Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C10W46E040 — Residual Current Protection
ParameterValue
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C10W46E040 — Electrical Ratings
ParameterValue
Rated current (In)40 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Overvoltage categoryIII
Electrical durability20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (operating cycles)20000 cycles
C10W46E040 — Identification
ParameterValue
Product nameComPacT NSX
Product / component typeCircuit breaker
Product range / familyComPacT
Device short nameNSX100HB2
C10W46E040 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical Flat on the back
Control typeToggle
C10W46E040 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C10W46E040 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The C10W46E040 is a Schneider Electric ComPacT NSX moulded-case circuit breaker rated 40 A at 40 °C, 4-pole, with a MicroLogic 6.2 E electronic trip unit. The 100 kA Icu at 690 V AC per IEC 60947-2 means it can safely interrupt fault currents up to that level on a 690 V line without upstream cascading — the HB2 breaking capacity code confirms that. The 6.2 E trip provides L (long-time overload), S (short-time short-circuit), I (instantaneous), and G (ground-fault) protection, plus an energy-meter function and LCD display for time-stamped event logs and power-quality data.

Selectivity and coordination

The electronic trip unit's LSI+G curves give the site engineer fine-grained selectivity with downstream breakers.

Four poles with neutral on the left. The 161 x 140 x 86 mm (H x W x D) footprint fits standard panel layouts.

Frequently asked questions

Who supplies C10W46E040 and how is it quoted for volume purchases?

C10W46E040 is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the closest pin-compatible alternative to C10W46E040 in this component family?

Within the ComPacT NSX family, a different trip-unit rating (e.g., a MicroLogic 2.2 or 5.2 E at 40 A) would share the same frame and footprint but change the protection curve and feature set — the physical mounting and connection pitch remain identical.