Schneider Electric C125H360FM — Residual Current Breakers (RCCB/RCBO)

C125H360FM ComPacT NS 3P 1250A, 85 kA Icu 240V AC

MPNC125H360FM
Active

Schneider Electric ComPacT NS new generation, C125H360FM, 3P, 1250 A at 50 °C, MicroLogic 6.0 electronic trip unit, 85 kA Icu at 240 V AC, EN/IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C125H360FM — Residual Current Protection
ParameterValue
Trip unit technologyElectronic
Local signalling / indication4 LEDs (red) for fault indication 1 LED (yellow) for overload
C125H360FM — Electrical Ratings
ParameterValue
Rated current (In)1250 A at 50 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz
Number of poles3P
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)8 kV conforming to IEC 60947-2
Overvoltage categoryIII
Electrical durability2000 cycles at 690 V In 3000 cycles at 690 V In/2 4000 cycles at 440 V In 5000 cycles at 440 V In/2
Mechanical durability (operating cycles)10000 cycles
C125H360FM — Identification
ParameterValue
Product nameComPacT NS new generation
Product / component typeCircuit breaker
Product range / familyComPacT
C125H360FM — Mechanical
ParameterValue
Mounting supportBackplate
Mounting modeFixed
Control typeManually operated
C125H360FM — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C125H360FM — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The C125H360FM is a fixed-mount, manually operated 3-pole ComPacT NS new generation molded-case circuit breaker from Schneider Electric. It carries a MicroLogic 6.0 electronic trip unit rated 1250 A at 50 °C, providing LSI protection (long-time, short-time, instantaneous) plus ground-fault (G) on the same trip unit. Breaking capacity reaches 85 kA Icu at 240 V AC and 70 kA Icu at 415 V AC per EN/IEC 60947-2. The 70 mm connection pitch and backplate mounting suit it for distribution switchboards where a high-amp feed needs coordination downstream.

At 415 V the Icu drops to 70 kA, still high enough to clear most industrial service-entrance faults without cascading upstream. The MicroLogic 6.0 trip unit is fully electronic, so it holds a thermal memory of 20 minutes — after a prolonged overload the breaker remembers the thermal history and shortens the next trip time, protecting cables and busbars from cumulative heating. Mechanical durability is rated at 10,000 cycles; electrical durability varies with load — 2,000 cycles at 690 V In, 4,000 cycles at 440 V In. That means in a high-cycle distribution feeder (frequent on/off switching), plan for contact maintenance or replacement earlier than the mechanical count suggests. The IP40 enclosure keeps out tools and small debris but not water — mount it in a dry, indoor panel.

The C125H360FM is current production. It is part of the ComPacT NS630b…1600 new generation family, the active platform replacing the earlier NS series.

Frequently asked questions

What is C125H360FM's breaking capacity at 415 V?

70 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2. The same breaker delivers 85 kA Icu at 240 V and 65 kA at 440 V.

MPN
C125H360FM