Skip to main content
Schneider Electric C125H360FM

C125H360FM ComPacT NS 3P 1250A, 85 kA Icu 240V AC

MPN C125H360FM
Active

Schneider Electric ComPacT NS new generation, C125H360FM, 3P, 1250 A at 50 °C, MicroLogic 6.0 electronic trip unit, 85 kA Icu at 240 V AC, EN/IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C125H360FM key specifications
ParameterValue
Control typeManually operated
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Utilization categoryCategory B
IP ratingIP40
Terminal pitch70 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C

All specifications

C125H360FM additional specifications
ParameterValue
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degree3 conforming to IEC 60947
Depth147 mm
Width210 mm
Height327 mm
Electrical life cycles2000 cycles at 690 V In 3000 cycles at 690 V In/2 4000 cycles at 440 V In 5000 cycles at 440 V In/2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The C125H360FM is a fixed-mount, manually operated 3-pole ComPacT NS new generation molded-case circuit breaker from Schneider Electric. It carries a MicroLogic 6.0 electronic trip unit rated 1250 A at 50 °C, providing LSI protection (long-time, short-time, instantaneous) plus ground-fault (G) on the same trip unit. Breaking capacity reaches 85 kA Icu at 240 V AC and 70 kA Icu at 415 V AC per EN/IEC 60947-2. The 70 mm connection pitch and backplate mounting suit it for distribution switchboards where a high-amp feed needs coordination downstream.

At 415 V the Icu drops to 70 kA, still high enough to clear most industrial service-entrance faults without cascading upstream. The MicroLogic 6.0 trip unit is fully electronic, so it holds a thermal memory of 20 minutes — after a prolonged overload the breaker remembers the thermal history and shortens the next trip time, protecting cables and busbars from cumulative heating. Mechanical durability is rated at 10,000 cycles; electrical durability varies with load — 2,000 cycles at 690 V In, 4,000 cycles at 440 V In. That means in a high-cycle distribution feeder (frequent on/off switching), plan for contact maintenance or replacement earlier than the mechanical count suggests. The IP40 enclosure keeps out tools and small debris but not water — mount it in a dry, indoor panel.

The C125H360FM is current production. It is part of the ComPacT NS630b…1600 new generation family, the active platform replacing the earlier NS series.

MPN
C125H360FM