Skip to main content
Schneider Electric C160H450FM — Miniature Circuit Breakers (MCB)

Schneider C160H450FM ComPacT NS 1600A, 70kA 415V, MicroLogic

MPNC160H450FM
Active

Schneider Electric ComPacT NS new generation, C160H450FM, fixed-mount 4P circuit breaker, 1600 A at 50 °C, MicroLogic 5.0 electronic trip unit, 70 kA Icu at 415 V AC, IEC 60947-2.

$8,670.19Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

C160H450FM — Identification
ParameterValue
Product nameComPacT NS new generation
Product rangeComPacT
Product range (series)ComPacT NS630b...1600 new generation
Product/component typeCircuit breaker
Device applicationDistribution
C160H450FM — Ratings
ParameterValue
Rated current (In)1600 A at 50 °C
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)37 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 37 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 37 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)8 kV conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory B
Overvoltage categoryIII
C160H450FM — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)1000 cycles at 690 V In 2000 cycles at 690 V In/2 2000 cycles at 440 V In 5000 cycles at 440 V In/2
Mechanical durability (cycles)10000 cycles
C160H450FM — Mechanical
ParameterValue
Mounting supportBackplate
Mounting modeFixed
Control typeManually operated
Local signalling/indication4 LEDs (red) for fault indication 1 LED (yellow) for overload
C160H450FM — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947
Relative humidity0...95 %
C160H450FM — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C160H450FM — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.4...1 x In
Trip unit protection functionsLSI

Product details

The C160H450FM is a Schneider ComPacT NS new generation 4-pole circuit breaker, rated 1600 A at 50 °C with a MicroLogic 5.0 electronic trip unit. This is the part you spec into a main switchboard or heavy distribution panel where you need L, S, and I protection curves configurable via the trip unit.

Drop to 690 V and it still holds 42 kA Icu, which covers most industrial step-down transformers. The IEC 60947-2 Category B rating means it's fully selective with downstream breakers, so a fault on a branch won't take the whole board dark. For a 1600 A main, that matters.

Trip unit and protection curves

The 20-minute thermal memory means it remembers prior heating after a trip — no nuisance reclose on a still-hot cable. Power losses are 74 W at rated current, which matters for ventilation calc in a sealed enclosure. Four red LEDs for fault type and one yellow for overload give you a quick diagnostic without plugging in a UTA.

Operates at 0–2000 m without derating; above that, up to 5000 m with derating. Humidity tolerance 0–95% non-condensing. Complies with EN/IEC 60947-2; no earth-leakage protection built in (that's a separate module).

Durability and service life

Mechanical durability is 10,000 cycles — the handle mechanism. Electrical durability depends on the load: 1000 cycles at full 690 V In, 2000 at half load, 5000 at 440 V full load, and 5000 at half load. That's typical for a fixed-mount breaker of this class; it's not a switching device for daily motor starts, but it handles infrequent manual operations and maintenance switching without issue.

Frequently asked questions

Who supplies C160H450FM and how is it quoted for volume purchases?

Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for volume pricing.

What is C160H450FM's breaking capacity at 415 V?

70 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2. The breaking capacity code is H, which corresponds to that 70 kA at 415 V.

What compliance documentation does this brand provide for C160H450FM?

The breaker is certified to EN/IEC 60947-2. IP40 per IEC 60529, IK07 per EN 50102. Pollution degree 3, overvoltage category III. No earth-leakage protection integrated.

What is the mounting configuration for C160H450FM?

Fixed mount on a backplate. 280 mm wide, 327 mm tall, 147 mm deep. Front connections both line and load. 70 mm connection pitch. Neutral on the left.

MPN
C160H450FM