Schneider Electric C160N42EFM — Miniature Circuit Breakers (MCB)

Schneider C160N42EFM ComPacT NS 1600A 4P 85kA 240V AC MCCB

MPNC160N42EFM
Active

Schneider Electric ComPacT NS new generation, C160N42EFM, 4P fixed MCCB, 1600 A at 50 °C, 85 kA Icu at 240 V AC, MicroLogic 2.0 E electronic trip unit, EN/IEC 60947-2.

$3,354.70Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

C160N42EFM — Identification
ParameterValue
Product nameComPacT NS new generation
Product rangeComPacT
Product range (series)ComPacT NS630b...1600 new generation
Product/component typeCircuit breaker
Device applicationDistribution
C160N42EFM — Ratings
ParameterValue
Rated current (In)1600 A at 50 °C
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)37 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 37 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 37 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)8 kV conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory B
Overvoltage categoryIII
C160N42EFM — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)1000 cycles at 690 V In 2000 cycles at 690 V In/2 2000 cycles at 440 V In 5000 cycles at 440 V In/2
Mechanical durability (cycles)10000 cycles
C160N42EFM — Mechanical
ParameterValue
Mounting supportBackplate
Mounting modeFixed
Control typeManually operated
Local signalling/indication4 LEDs (red) for fault indication 1 LED (yellow) for overload
C160N42EFM — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947
Relative humidity0...95 %
C160N42EFM — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C160N42EFM — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.4...1 x In
Trip unit protection functionsLI

Product details

The C160N42EFM is a 4-pole fixed-mount ComPacT NS new generation MCCB from Schneider Electric, rated 1600 A at 50 °C with an electronic MicroLogic 2.0 E trip unit that provides overload (L) and instantaneous short-circuit (I) protection. Its 85 kA Icu at 240 V AC and 50 kA at 415 V AC (per IEC 60947-2) means it can interrupt high fault currents without upstream cascading — a key spec for distribution panels where available fault current is high. The LCD display and energy-metering measurement type let you track load data directly at the breaker, which saves a panel builder from adding a separate power meter.

Trip unit and protection logic

The MicroLogic 2.0 E is an electronic trip unit with a 20-minute thermal memory — after a trip, it remembers the heat history so re-closing too soon doesn't cause nuisance tripping on a still-hot breaker. That matters on motor or transformer feeders where the load might re-energise while the internal temperature is still elevated. Protection is L (long-time overload) and I (instantaneous short-circuit); no short-time or ground-fault curve here, so it's suited for distribution rather than selective coordination downstream.

Mechanical and electrical endurance

Rated for 10,000 mechanical cycles and 1,000 electrical cycles at full rated current (690 V), with higher counts at reduced loads — 2,000 cycles at In/2 and 5,000 cycles at 440 V In/2. That's typical for a fixed-mount distribution breaker; it's not a switching device for frequent motor starts, but it handles routine isolation and fault clearing without wearing out early.

Fixed mount on a backplate, front-connected top and bottom, with a 70 mm connection pitch.

Frequently asked questions

What is the breaking capacity of C160N42EFM at 415 V?

50 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2.

What trip unit does the C160N42EFM use?

It uses a MicroLogic 2.0 E electronic trip unit with L (long-time overload) and I (instantaneous short-circuit) protection.

Where can I buy C160N42EFM and how is it quoted?

The C160N42EFM is sourced to order through independent distribution. Submit an RFQ for current availability and pricing — no stock or price figures are published here.

MPN
C160N42EFM