Schneider Electric C16F4D — Miniature Circuit Breakers (MCB)

Schneider Electric C16F4D ComPacT NSX160F DC, 160A, 36kA at

MPNC16F4D
Active

Schneider Electric ComPacT NSX DC series, NSX160F DC basic frame, 160 A, 36 kA Icu at 750 V DC, 4 poles, without trip unit, toggle control, fixed mount.

$324.49 – $335.34Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C16F4D — Identification
ParameterValue
Product nameComPacT NSX DC
Product rangeComPacT
Product/component typeBasic frame
Device applicationDistribution
C16F4D — Ratings
ParameterValue
Rated current (In)160 A at 40 °C
Poles configuration4P
Breaking capacity36 kA Icu at 250 V DC 1P conforming to IEC 60947-2 36 kA Icu at 24...125 V DC 1P conforming to IEC 60947-2 36 kA Icu at 500 V DC 2P conforming to IEC 60947-2 36 kA Icu at 750 V DC 3P conforming to IEC 60947-2
Rated service breaking capacity (Ics)36 kA at 250 V DC conforming to IEC 60947-2 (1P) 36 kA at 24...125 V DC conforming to IEC 60947-2 (1P) 36 kA at 500 V DC conforming to IEC 60947-2 (2P) 36 kA at 750 V DC conforming to IEC 60947-2 (3P)
Rated operational voltage (Ue)750 V DC conforming to IEC 60947-2
Rated insulation voltage (Ui)750 V DC conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)8 kV conforming to IEC 60947-2
Network type (AC/DC)DC
Utilisation categoryCategory A
Overvoltage categoryIII
C16F4D — Protection
ParameterValue
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)10000 cycles 250 V DC In/2 conforming to IEC 60947-2 10000 cycles 500 V DC In/2 conforming to IEC 60947-2 10000 cycles 750 V DC In/2 conforming to IEC 60947-2 5000 cycles 250 V DC In conforming to IEC 60947-2 5000 cycles 500 V DC In conforming to IEC 60947-2 5000 cycles 750 V DC In conforming to IEC 60947-2
Mechanical durability (cycles)10000 cycles conforming to IEC 60947-2
C16F4D — Mechanical
ParameterValue
Mounting supportBackplate
Mounting modeFixed
Control typeToggle
C16F4D — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
C16F4D — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

ComPacT NSX160F DC — 160 A basic frame, 36 kA at 750 V DC

The C16F4D is a Schneider Electric ComPacT NSX160F DC basic frame — a 4-pole, fixed-mount circuit breaker frame rated 160 A at 40 °C, with a 36 kA Icu breaking capacity at 750 V DC per EN/IEC 60947-2. It ships without a trip unit (basic frame), so you select and install the appropriate electronic or Micrologic trip unit separately for the protection curve your DC distribution bus requires. The 36 kA Icu holds across the full DC voltage range: 250 V DC (1P), 500 V DC (2P), and 750 V DC (3P). The Ics (service breaking capacity) matches the Icu at 36 kA — meaning after clearing a fault at rated capacity the frame remains functional, not just safe. That matters for selectivity studies on DC bus feeds where fault current can hit 30+ kA. Rated insulation voltage (Ui) and operational voltage (Ue) both sit at 750 V DC, with an impulse withstand (Uimp) of 8 kV.

Fixed-mount on a backplate, 140 mm wide × 161 mm high × 86 mm deep. The 35 mm connection pitch and front-facing connections (both upside and downside) simplify busbar and cable routing in a standard panel layout. Neutral position is left; the toggle control is front-accessible. IP40 front face, IK07 impact resistance — adequate for enclosed industrial switchboards, not for washdown zones.

Mechanical durability is 10,000 cycles; electrical durability varies by load: 10,000 cycles at In/2 (250 V, 500 V, 750 V DC) and 5,000 cycles at full rated current. Maximum breaking time is 10 ms.

Frequently asked questions

Where can I buy C16F4D and how do I get a price?

The C16F4D is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is C16F4D's breaking capacity at 750 V DC?

The C16F4D has a 36 kA Icu (ultimate breaking capacity) at 750 V DC per EN/IEC 60947-2, with the Ics (service breaking capacity) also rated at 36 kA.

What compliance standards does C16F4D meet?

The C16F4D is designed and certified to EN/IEC 60947-2, with a rated insulation voltage of 750 V DC, pollution degree 3 per IEC 60664-1, and overvoltage category III. It is suitable for isolation per the same standard.