Skip to main content
Schneider Electric C16N44V100 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric C16N44V100 ComPacT NSX160N, 100A, 50kA 41

MPNC16N44V100
Active

Schneider Electric ComPacT NSX series, C16N44V100, 4-pole MCCB with MicroLogic 4.2 electronic trip unit, 100 A rating, 50 kA breaking capacity at 415 V AC.

$1,221.79 – $2,527.20Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C16N44V100 — Residual Current Protection
ParameterValue
Earth-leakage protection class / typeClass A
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C16N44V100 — Electrical Ratings
ParameterValue
Rated current (In)100 A at 40 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Overvoltage categoryIV
Electrical durability40000 cycles at 440 V In/2 20000 cycles at 440 V In 15000 cycles at 690 V In/2 7500 cycles at 690 V In
Mechanical durability (operating cycles)40000 cycles
C16N44V100 — Identification
ParameterValue
Product nameComPacT NSX
Product / component typeEarth leakage circuit breaker
Product range / familyComPacT
Device short nameNSX160N
C16N44V100 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical Flat on the back
Control typeToggle
C16N44V100 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C16N44V100 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The Schneider Electric C16N44V100 is a ComPacT NSX160N moulded-case circuit breaker — a 4-pole, 100 A frame with an electronic MicroLogic 4.2 trip unit.

Trip unit and protection logic

The MicroLogic 4.2 is an electronic trip unit that provides L (long-time overload), So (short-time short-circuit with fixed delay), I (instantaneous short-circuit), and R (earth-leakage) protection. The earth-leakage protection is integrated into the breaker — no external module needed. A 20-minute thermal memory means the breaker remembers a prior overload event and will trip faster on a reclose into a still-hot conductor, which is useful for motor or transformer feeders that see repeated starts.

Breaking capacity across voltages

The C16N44V100 is rated per EN/IEC 60947-2 with the following Icu: 90 kA at 220/240 V AC, 50 kA at 380/415 V AC, 50 kA at 440 V AC, 36 kA at 500 V AC, 35 kA at 525 V AC, and 10 kA at 660/690 V AC. It also carries UL 60947-4-1 ratings: 85 kA at 240 V AC, 50 kA at 480 V AC, and 10 kA at 600 V AC. The utilisation category is A — not intended for current-limiting applications, but suitable for general distribution and feeder protection where selectivity with downstream breakers is designed in.

Physical fit and mounting

Mounts on a backplate in horizontal or vertical orientation, flat on the back. Front connections on both upside and downside. Connection pitch is 35 mm. Neutral is on the left. IP40 protection — suitable for indoor panel installation; IK07 impact resistance.

Durability and operational life

Mechanical durability is 40,000 cycles. Electrical durability varies by load: 40,000 cycles at 440 V at half rated current (In/2), 20,000 cycles at 440 V at full In, 15,000 cycles at 690 V at In/2, and 7,500 cycles at 690 V at full In. These numbers matter for a breaker that sees frequent switching — like a main disconnect on a machine that cycles every shift.

Frequently asked questions

How do I get current pricing and availability for C16N44V100?

Submit an RFQ through the storefront. The C16N44V100 is sourced to order through independent distribution; pricing and stock levels are confirmed at quote time.

What is the closest alternative to C16N44V100 in the ComPacT NSX family?

Within the ComPacT NSX160N frame, the primary alternative is a different trip-unit rating or breaking-capacity code. The C16N44V100 is the 100 A, 4P, N-breaking-capacity (50 kA at 415 V) variant with MicroLogic 4.2 and integrated earth-leakage. A 100 A, 3P version would be a different order code; a higher breaking capacity (S or H code) would also be a different part number. No pin-compatible drop-in exists within the same frame — the trip unit and poles are fixed.

What compliance documentation does the C16N44V100 carry?

The C16N44V100 is certified to EN/IEC 60947-2 and UL 60947-4-1. The IP40 rating is per IEC 60529, and the IK07 rating is per IEC 62262. Pollution degree 3 and overvoltage category IV are per IEC 60664-1. The evidence does not list RoHS or REACH declarations, but as a current Schneider catalog item it typically ships with a CE declaration and a manufacturer's declaration of conformity available on request.