Skip to main content
Schneider Electric C25F44V250 — Residual Current Breakers (RCCB/RCBO)

Schneider C25F44V250 ComPacT NSX250F MCCB, 250A, 85kA Icu

MPNC25F44V250
Active

Schneider Electric ComPacT NSX series, NSX250F, 4-pole MCCB, 250 A, 85 kA Icu at 240 V AC, MicroLogic 4.2 electronic trip unit with integrated earth-leakage protection.

$1,322.27 – $2,913.84Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C25F44V250 — Residual Current Protection
ParameterValue
Earth-leakage protection class / typeClass A
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C25F44V250 — Electrical Ratings
ParameterValue
Rated current (In)250 A at 40 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Overvoltage categoryIV
Electrical durability20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (operating cycles)20000 cycles
C25F44V250 — Identification
ParameterValue
Product nameComPacT NSX
Product / component typeEarth leakage circuit breaker
Product range / familyComPacT
Device short nameNSX250F
C25F44V250 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical Flat on the back
Control typeToggle
C25F44V250 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C25F44V250 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The Schneider Electric C25F44V250 is a ComPacT NSX250F 4-pole moulded-case circuit breaker (MCCB) from the ComPacT NSX family, fitted with a MicroLogic 4.2 electronic trip unit.

Across the voltage range it delivers 85 kA Icu at 220/240 V AC, 36 kA at 380/415 V, 35 kA at 440 V, 30 kA at 500 V, 22 kA at 525 V, and 8 kA at 660/690 V, all per IEC 60947-2. Under UL 60947-4-1 it is rated 85 kA at 240 V, 35 kA at 480 V, and 15 kA at 600 V AC. For a buyer specifying into a 415 V panel, the 36 kA Icu gives headroom above typical 25 kA or 35 kA fault levels common in commercial distribution — you can use it downstream of a transformer without worrying about cascading failure on a bolted fault. The 85 kA at 240 V also makes it suitable for 240 V delta or split-phase services where fault currents can be high.

Trip unit and protection logic

The MicroLogic 4.2 is an electronic trip unit — not a thermal-magnetic — which means it holds its trip curve tighter across ambient temperature swings and offers adjustable long-time pickup and delay. Earth-leakage protection is integrated (no external toroid or relay needed), adjustable via the IΔn rotary switch. The trip unit is rated 250 A at 40 °C; above that temperature the breaker must be derated per the manufacturer's curve, but the 40 °C baseline covers most enclosed panel environments. The electronic design also enables local signalling: a green flashing LED for ready-to-operate, red LED at 105 % Ir for overload, and orange LED at 90 % Ir as a pre-alarm.

Physical fit and installation

The breaker measures 161 mm high by 140 mm wide by 86 mm deep, with a 35 mm connection pitch. Both line and load connections are front-facing, which simplifies busbar and cable routing in a switchboard. The IK07 impact rating confirms it can withstand a 2 J impact, which covers accidental tool drops during maintenance.

Frequently asked questions

What is C25F44V250's breaking capacity at 415 V?

The C25F44V250 carries the 'F' breaking capacity code: 36 kA Icu at 380/415 V AC per IEC 60947-2.

Does the C25F44V250 include earth-leakage protection?

Yes, earth-leakage protection is integrated into the MicroLogic 4.2 trip unit, adjustable via the IΔn rotary switch.

Where can I buy C25F44V250 and what is the lead time?

The C25F44V250 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance documentation does Schneider provide for C25F44V250?

The breaker is certified to EN/IEC 60947-2 and UL 60947-4-1. It carries IP40 and IK07 protection ratings per IEC 60529 and IEC 62262 respectively, and is rated for pollution degree 3 per IEC 60664-1.

MPN
C25F44V250