Schneider Electric C40F34V400 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric C40F34V400 ComPacT NSX400F MCCB, 400 A, 4

MPNC40F34V400
Active

Schneider Electric ComPacT NSX series, C40F34V400, 3P earth leakage MCCB, 400 A at 40 °C, 36 kA Icu at 415 V AC, MicroLogic 4.3 electronic trip unit, integrated earth-leakage protection.

$1,782.43 – $4,278.96Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C40F34V400 — Residual Current Protection
ParameterValue
Earth-leakage protection class / typeClass A
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C40F34V400 — Electrical Ratings
ParameterValue
Rated current (In)400 A at 40 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz
Poles description3P
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Overvoltage categoryIV
Electrical durability12000 cycles at 440 V In/2 6000 cycles at 440 V In 6000 cycles at 690 V In/2 3000 cycles at 690 V In
Mechanical durability (operating cycles)15000 cycles
C40F34V400 — Identification
ParameterValue
Product nameComPacT NSX
Product / component typeEarth leakage circuit breaker
Product range / familyComPacT
Device short nameNSX400F
C40F34V400 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical Flat on the back
Control typeToggle
C40F34V400 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C40F34V400 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The C40F34V400 is a 3-pole ComPacT NSX400F earth-leakage circuit breaker from Schneider Electric, rated 400 A at 40 °C with a MicroLogic 4.3 electronic trip unit. The 36 kA Icu at 415 V AC (per EN/IEC 60947-2) is the breaking capacity that governs most European 400 V distribution panels — it tells you this breaker safely interrupts a fault up to 36 kA without failing, which is the figure a panel builder uses for SCCR coordination downstream. The 400 A trip rating means it protects a 400 A feeder or a large motor control center bus; the electronic trip unit gives adjustable long-time (L), short-time (So), instantaneous (I), and earth-leakage (R) protection curves, so you set the trip thresholds to the load, not the other way around. Integrated earth-leakage protection (R function) is built into the trip unit — no external RCD module needed. The 20-minute thermal memory before and after tripping means the breaker remembers the thermal state of the conductors even after a short interruption, preventing nuisance re-closure on a still-hot circuit. Mounting is backplate, horizontal or vertical, with front connections top and bottom; the 140 mm width and 255 mm height fit standard ComPacT NSX cutouts.

The F breaking capacity code delivers 36 kA Icu at 415 V AC, but the same breaker is rated 40 kA at 240 V, 30 kA at 440 V, 25 kA at 500 V, 20 kA at 525 V, and 10 kA at 690 V.

Panel integration and environmental ratings

IP40 front face (finger-safe against tools >1 mm) and IK07 impact resistance per IEC 62262 — suitable for enclosed distribution boards where incidental contact is possible. The 110 mm depth fits standard NSX enclosures; backplate mounting with horizontal or vertical orientation gives flexibility in tight cabinets.

Frequently asked questions

What is the breaking capacity of C40F34V400 at 415 V?

The C40F34V400 is rated 36 kA Icu at 380/415 V AC 50/60 Hz per EN/IEC 60947-2, which is the standard figure for European 400 V distribution panels.

What protection functions does the MicroLogic 4.3 trip unit provide?

The MicroLogic 4.3 electronic trip unit provides long-time overload (L), short-time short-circuit with fixed delay (So), instantaneous short-circuit (I), and integrated earth-leakage (R) protection — all adjustable via the rotary switches on the front face.

Where can I buy C40F34V400 and how is it quoted?

The C40F34V400 is sourced and quoted to order against an RFQ through independent industrial-automation distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.