Skip to main content
Schneider Electric C60H4P20AB — 2-Pole MCB (DIN Rail)

Schneider Electric C60H4P20AB MCB, 20 A, 4P, B Curve, 10 kA

MPNC60H4P20AB
Obsolete

Schneider Electric Multi9 C60H MCB, C60H4P20AB, 20 A, 4P, B curve, 10 kA Icn at 230/400 V AC, thermal-magnetic trip, 35 mm DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C60H4P20AB — Identification
ParameterValue
Product nameC60
Product rangeC60
Series / familyMulti9
Device short nameC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
C60H4P20AB — Electrical
ParameterValue
Rated current [In]20 A at 30 °C
Number of protected poles4
Pole configuration4P
Rated operational voltage [Ue]12...440 V AC 50/60 Hz
Network type (AC/DC)AC DC
Network frequency50/60 Hz
C60H4P20AB — Protection
ParameterValue
Tripping curve codeB
Magnetic tripping limit3...5 x In
Breaking capacity (Icu)10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2
Rated service breaking capacity [Ics]7.5 kA conforming to EN 60898 - 230/400 V AC 50/60 Hz 15 kA conforming to IEC 60947-2 - 230...240 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 - 440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 400...415 V AC 50/60 Hz
Energy limitation class3 conforming to IEC 60947-2
Suitable for isolationYes conforming to IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
C60H4P20AB — Mechanical
ParameterValue
9 mm pitches8
Width72 mm
Height81 mm
Depth73 mm
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Terminal connectionsTunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid
Terminal tightening torquePower circuit: 2 N.m upside 2 N.m downside
Comb busbar / distribution block compatibilityNO
Local signalling / indicationON/OFF indication
Contact position indicatorYes
C60H4P20AB — Environmental
ParameterValue
Operating temperature range-25...60 °C
Storage temperature range-40...70 °C
Relative humidity95 % at 55 °C
C60H4P20AB — Approvals
ParameterValue
Standards / complianceEN 60898 IEC 60947-2

Product details

The Schneider Electric C60H4P20AB is a 4-pole miniature circuit breaker from the Multi9 C60H range, rated 20 A at 30 °C with a B-curve trip characteristic (magnetic tripping between 3 and 5 times In). It carries a 10 kA Icn breaking capacity at 230/400 V AC per EN 60898, and higher Icu ratings per IEC 60947-2: 15 kA at 400...415 V AC, 30 kA at 230...240 V AC, and 50 kA at 250 V DC for the 4-pole configuration.

Under IEC 60947-2 for industrial applications, the Icu (ultimate breaking capacity) reaches 30 kA at 230...240 V AC and 15 kA at 400...415 V AC. The Ics (service breaking capacity) is 7.5 kA at 230/400 V AC per EN 60898, meaning the breaker can be reclosed after clearing a fault at that level without replacement. The 4-pole DC rating of 50 kA Icu at 250 V DC makes it suitable for DC distribution panels in telecom or solar combiner boxes.

Installation and wiring

Fixed mounting on 35 mm DIN rail. The toggle actuator provides ON/OFF local indication and a contact position indicator confirms isolation status per IEC 60947-2. The 4-pole unit occupies 8 x 9 mm pitches (72 mm wide, 81 mm high, 73 mm deep).

Frequently asked questions

What is the breaking capacity of C60H4P20AB?

The C60H4P20AB has a 10 kA Icn at 230/400 V AC per EN 60898. Under IEC 60947-2, the Icu is 30 kA at 230...240 V AC, 15 kA at 400...415 V AC, and 50 kA at 250 V DC for the 4-pole configuration. The Ics is 7.5 kA at 230/400 V AC per EN 60898.

What is the rated current and curve of C60H4P20AB?

Rated current is 20 A at 30 °C with a B curve, meaning magnetic tripping occurs between 3 and 5 times the rated current (60 to 100 A).

What compliance documentation does Schneider provide for C60H4P20AB?

The breaker is certified to EN 60898 and IEC 60947-2. It carries tropicalisation level 2 per IEC 60068-1 and limitation class 3 per IEC 60947-2. Specific RoHS/REACH/UL documentation should be confirmed at quote time.

Who supplies C60H4P20AB and how is it quoted for volume purchases?

C60H4P20AB is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time for any volume.

MPN
C60H4P20AB