Schneider Electric C60H4P20AB

Schneider Electric C60H4P20AB MCB, 20 A, 4P, B Curve, 10 kA

MPN C60H4P20AB
Obsolete

Schneider Electric Multi9 C60H MCB, C60H4P20AB, 20 A, 4P, B curve, 10 kA Icn at 230/400 V AC, thermal-magnetic trip, 35 mm DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C60H4P20AB specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage12...440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
Depth73 mm
Width72 mm
Height81 mm
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric C60H4P20AB is a 4-pole miniature circuit breaker from the Multi9 C60H range, rated 20 A at 30 °C with a B-curve trip characteristic (magnetic tripping between 3 and 5 times In). It carries a 10 kA Icn breaking capacity at 230/400 V AC per EN 60898, and higher Icu ratings per IEC 60947-2: 15 kA at 400...415 V AC, 30 kA at 230...240 V AC, and 50 kA at 250 V DC for the 4-pole configuration.

Under IEC 60947-2 for industrial applications, the Icu (ultimate breaking capacity) reaches 30 kA at 230...240 V AC and 15 kA at 400...415 V AC. The Ics (service breaking capacity) is 7.5 kA at 230/400 V AC per EN 60898, meaning the breaker can be reclosed after clearing a fault at that level without replacement. The 4-pole DC rating of 50 kA Icu at 250 V DC makes it suitable for DC distribution panels in telecom or solar combiner boxes.

Installation and wiring

Fixed mounting on 35 mm DIN rail. The toggle actuator provides ON/OFF local indication and a contact position indicator confirms isolation status per IEC 60947-2. The 4-pole unit occupies 8 x 9 mm pitches (72 mm wide, 81 mm high, 73 mm deep).

MPN
C60H4P20AB