The C60H4P40AD is a 4-pole miniature circuit breaker from Schneider Electric's Multi9 C60 range, rated 40 A at 40 °C. The 10 kA Icn at 230/400 V AC per EN 60898 covers standard commercial panel fault levels; the IEC 60947-2 ratings give higher Icu values for industrial coordination — 15 kA at 400-415 V, 30 kA at 230-240 V, and up to 50 kA at 250 V DC for the 4P configuration. That DC breaking capacity makes it usable in battery or UPS circuits where the poles are series-connected. Snaps onto a 35 mm symmetrical DIN rail, 4 modules wide at 72 mm, 81 mm tall, 73 mm deep. Thermal-magnetic trip technology with separate earth-leakage block option — the MCB itself does not include integral RCD. Suitability for isolation marked per IEC 60947-2.

Schneider Electric C60H4P40AD C60 MCB, 40 A, D Curve, 4P, 10
MPNC60H4P40AD
Obsolete
Schneider Electric Multi9 C60 series, C60H4P40AD, miniature circuit breaker, 40 A, D curve, 4 poles, 10 kA Icn at 230/400 V AC.
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Product name | C60 |
| Product range | C60 |
| Series / family | Multi9 |
| Device short name | C60H |
| Product / component type | Miniature circuit-breaker |
| Device application | Distribution |
| Parameter | Value |
|---|---|
| Rated current [In] | 40 A at 40 °C |
| Number of protected poles | 4 |
| Pole configuration | 4P |
| Rated operational voltage [Ue] | 12...440 V AC 50/60 Hz |
| Network type (AC/DC) | DC AC |
| Network frequency | 50/60 Hz |
| Parameter | Value |
|---|---|
| Tripping curve code | D |
| Magnetic tripping limit | 10...14 x In |
| Breaking capacity (Icu) | 10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2 |
| Rated service breaking capacity [Ics] | 7.5 kA conforming to EN 60898 - 230/400 V AC 50/60 Hz 15 kA conforming to IEC 60947-2 - 230...240 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 - 440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 400...415 V AC 50/60 Hz |
| Energy limitation class | 3 conforming to IEC 60947-2 |
| Suitable for isolation | Yes conforming to IEC 60947-2 |
| Trip unit technology | Thermal-magnetic |
| Earth-leakage protection | Separate block |
| Operating / control type | Toggle |
| Mechanical durability (cycles) | 20000 cycles |
| Parameter | Value |
|---|---|
| 9 mm pitches | 8 |
| Width | 72 mm |
| Height | 81 mm |
| Depth | 73 mm |
| Mounting support | 35 mm symmetrical DIN rail |
| Mounting mode | Fixed |
| Terminal connections | Tunnel type terminals25 mm² flexible Tunnel type terminals35 mm² rigid |
| Terminal tightening torque | Power circuit: 3.5 N.m upside 3.5 N.m downside |
| Comb busbar / distribution block compatibility | NO |
| Local signalling / indication | ON/OFF indication |
| Contact position indicator | Yes |
| Parameter | Value |
|---|---|
| Operating temperature range | -25...60 °C |
| Storage temperature range | -40...70 °C |
| Relative humidity | 95 % at 55 °C |
| Parameter | Value |
|---|---|
| Standards / compliance | EN 60898 IEC 60947-2 |
Product details
Frequently asked questions
Where can I buy the C60H4P40AD?
Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.
What is the C60H4P40AD's depth?
73 mm.
What standards does the C60H4P40AD comply with?
EN 60898 and IEC 60947-2. It also carries suitability for isolation per IEC 60947-2 and tropicalisation class 2 per IEC 60068-1.
MPN
C60H4P40AD