Skip to main content
Schneider Electric C60H4P63AB — 2-Pole MCB (DIN Rail)

Schneider Electric C60H4P63AB Miniature Circuit Breaker, 63

MPNC60H4P63AB
Obsolete

Schneider Electric Multi9 C60H series, C60H4P63AB, 4-pole miniature circuit breaker, B-curve, 63 A, thermal-magnetic, 10 kA breaking capacity, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C60H4P63AB — Identification
ParameterValue
Product nameC60
Product rangeC60
Series / familyMulti9
Device short nameC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
C60H4P63AB — Electrical
ParameterValue
Rated current [In]63 A at 30 °C
Number of protected poles4
Pole configuration4P
Rated operational voltage [Ue]12...440 V AC 50/60 Hz
Network type (AC/DC)DC AC
Network frequency50/60 Hz
C60H4P63AB — Protection
ParameterValue
Tripping curve codeB
Magnetic tripping limit3...5 x In
Breaking capacity (Icu)10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2
Rated service breaking capacity [Ics]7.5 kA conforming to EN 60898 - 230/400 V AC 50/60 Hz 15 kA conforming to IEC 60947-2 - 230...240 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 - 440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 400...415 V AC 50/60 Hz
Energy limitation class3 conforming to IEC 60947-2
Suitable for isolationYes conforming to IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
C60H4P63AB — Mechanical
ParameterValue
9 mm pitches8
Width72 mm
Height81 mm
Depth73 mm
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Terminal connectionsTunnel type terminals25 mm² flexible Tunnel type terminals35 mm² rigid
Terminal tightening torquePower circuit: 3.5 N.m upside 3.5 N.m downside
Comb busbar / distribution block compatibilityNO
Local signalling / indicationON/OFF indication
Contact position indicatorYes
C60H4P63AB — Environmental
ParameterValue
Operating temperature range-25...60 °C
Storage temperature range-40...70 °C
Relative humidity95 % at 55 °C
C60H4P63AB — Approvals
ParameterValue
Standards / complianceIEC 60947-2 EN 60898

Product details

The Schneider Electric C60H4P63AB is a 4-pole miniature circuit breaker from the Multi9 C60H series, rated at 63 A with a B-curve trip characteristic (3–5 × In magnetic tripping limit). It occupies 8 × 9 mm pitches on a 35 mm symmetrical DIN rail, so it takes 72 mm of rail width in the enclosure. The B-curve magnetic trip activates between 3 and 5 times the rated current. That suits resistive and general-purpose loads with modest inrush.

Dual-certified to IEC 60947-2 and EN 60898, this breaker carries a 10 kA Icn at 230/400 V AC under EN 60898 and a range of Icu values under IEC 60947-2: 15 kA at 400–415 V AC, 30 kA at 230–240 V AC, and 25 kA at 125 V DC (2-pole series connection). The Ics service breaking capacity sits at 7.5 kA for the 230/400 V AC EN 60898 case — meaning after clearing a fault at that level the breaker remains functional, not just safe. The thermal-magnetic trip unit handles overloads thermally and short-circuits magnetically. Rated insulation voltage is 500 V AC, and the operational voltage range covers 12–440 V AC 50/60 Hz.

Integration notes

The toggle provides local ON/OFF indication, and the contact position indicator confirms isolation visually. Maximum operating altitude is 2000 m without derating.

Frequently asked questions

What is the breaking capacity of C60H4P63AB?

The C60H4P63AB carries a 10 kA Icn at 230/400 V AC per EN 60898, and under IEC 60947-2 it achieves up to 30 kA Icu at 230–240 V AC and 15 kA Icu at 400–415 V AC. DC ratings reach 25 kA at 125 V DC (2-pole) and 40 kA at 125 V DC (3-pole).

MPN
C60H4P63AB