Specifications

C63F44V570 — Residual Current Protection
ParameterValue
Earth-leakage protection class / typeClass A
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C63F44V570 — Electrical Ratings
ParameterValue
Rated current (In)570 A at 40 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Overvoltage categoryIV
Electrical durability8000 cycles at 440 V In/2 4000 cycles at 440 V In 6000 cycles at 690 V In/2 2000 cycles at 690 V In
Mechanical durability (operating cycles)15000 cycles
C63F44V570 — Identification
ParameterValue
Product nameComPacT NSX
Product / component typeEarth leakage circuit breaker
Product range / familyComPacT
Device short nameNSX630F
C63F44V570 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical Flat on the back
Control typeToggle
C63F44V570 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C63F44V570 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

Integrator note — ComPacT NSX630F, 570 A, 4P

The C63F44V570 is a Schneider Electric ComPacT NSX630F moulded-case circuit breaker with a 570 A electronic trip unit (MicroLogic 4.3) at 40 °C, four poles, and an F breaking-capacity code — 36 kA Icu at 415 V AC per IEC 60947-2.

Breaking capacity — what the F code means

The F breaking-capacity code gives 36 kA Icu at 380/415 V AC and 40 kA at 220/240 V AC. At 440 V it drops to 30 kA; at 525 V to 20 kA; at 690 V to 10 kA. That's the full interrupting rating per IEC 60947-2 — the breaker can clear a fault at those levels and still be reclosed. For UL 60947-4-1 applications (motor-circuit protectors), the same breaker carries 85 kA Icu at 240 V AC, 35 kA at 480 V, and 20 kA at 600 V. If your panel is UL-listed, use those numbers for the SCCR calculation.

Backplate-mounted, flat on the back, horizontal or vertical orientation. The 4-pole unit is 185 mm wide, 255 mm high, 110 mm deep — fits a standard distribution panel footprint. Front connections top and bottom; neutral on the left. Overvoltage category IV — suitable for main incoming supply. Ambient humidity 0–95 % non-condensing; altitude up to 2000 m without derating, 2000–5000 m with derating.

Frequently asked questions

What is C63F44V570's listed range and series?

It belongs to the Schneider Electric ComPacT range, product name ComPacT NSX, device short name NSX630F.

What compliance documentation does Schneider Electric provide for C63F44V570?

The breaker is certified to EN/IEC 60947-2 and UL 60947-4-1 standards. Pollution degree 3 per IEC 60664-1, overvoltage category IV, IP40, IK07. No RoHS/REACH declarations are in this evidence, but standard Schneider Electric compliance documentation applies.

MPN
C63F44V570