Schneider Electric DF2FGA20 — Contactors

Schneider Electric DF2FGA20 TeSys GS NH000 Fuse, 20A, 690VAC

MPNDF2FGA20
Obsolete

Schneider Electric TeSys GS, DIN cartridge fuse, NH000, aM curve, 690VAC, 20A, set of 3, without striker.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

DF2FGA20 — Identification
ParameterValue
Product / component typeFuses
Series / rangeTeSys
DF2FGA20 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)690 V AC
DF2FGA20 — Other specifications
ParameterValue
Fuse sizeNH000
Fuse typeDIN
Fuse curveAM
Quantity per setSet of 3
Range of productDF
Device short nameblade fuse
Device applicationProtection
Current20 A

Product details

The DF2FGA20 is a DIN NH000 blade fuse from the TeSys GS range, rated 20 A at 690 V AC with an aM (motor-protection) curve. It comes as a set of three, without striker, and is designed for protection duty in industrial control panels — think motor branch circuits, feeder protection, or general short-circuit backup where the aM characteristic lets it ride through motor inrush without nuisance blowing.

The NH000 fuse size is the physical blade format — it slots into a matching NH000 fuse holder or disconnect switch (like the TeSys GS fuse switch disconnectors). The aM curve means it's a motor-protection fuse: it allows the high inrush current of a motor start (typically 6-8x FLA for a few seconds) without opening, but clears fast on a hard short. At 20 A and 690 V AC, it covers a 3-phase motor load up to roughly 7.5 kW at 400 V or 11 kW at 690 V — but always size to the motor full-load amps, not the fuse rating. The 690 V AC rating gives you headroom on 400 V or 480 V systems; just watch that the voltage rating is AC only, not DC.

Integration note — panel fit and marking

These mount in a standard DIN NH000 fuse holder or switch — no special tooling. The set-of-3 format is typical for 3-phase protection; each fuse is individually replaceable. No striker means no auxiliary contact to signal a blown fuse — if you need blown-fuse indication, you'd need a striker version or an external fuse monitor. The aM curve is printed on the fuse body; keep the packaging label for traceability if your QA process requires it.

Frequently asked questions

What is the DF2FGA20's fuse size and curve?

It is an NH000 blade fuse with an aM (motor-protection) curve. The NH000 size fits standard NH000 fuse holders or switch disconnectors. The aM curve means it handles motor inrush without nuisance tripping but clears fast on short circuits.

What voltage and current is the DF2FGA20 rated for?

Rated 20 A continuous current and 690 V AC operational voltage. That covers 400 V and 480 V three-phase systems with margin. The rating is AC only — not suitable for DC circuits.

Does the DF2FGA20 come as a single fuse or a set?

It comes as a set of three fuses, which is the standard quantity for protecting a three-phase motor branch circuit. Each fuse is individually replaceable.