Schneider Electric ENW21413 — Air Circuit Breakers

ENW21413 EasyPac NW Trip System 2.0E, 800-4000 A

MPNENW21413
Active

Schneider Electric EasyPact NW, Trip System 2.0E, control unit ENW21413, drawout, 800-4000 A, 690 V AC, LI protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

ENW21413 — Identification
ParameterValue
Product typeControl unit
Product rangeEasyPact NW
ENW21413 — Electrical ratings
ParameterValue
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P 4P
Network typeAC
Network frequency50/60 Hz
ENW21413 — Mechanical & connection
ParameterValue
Mounting modeDrawout
Width55 mm
Height200 mm
Depth75 mm
Neutral pole positionLeft
ENW21413 — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-25...85 °C

Product details

Trip unit for EasyPact NW drawout breakers

The ENW21413 is a Trip System 2.0E microprocessor-based control unit for Schneider Electric EasyPact NW drawout circuit breakers. It provides LI protection — long-time overload and instantaneous short-circuit — with an adjustable trip unit rating from 800 to 4000 A, making it the brains for large industrial power distribution on 690 V AC networks at 50/60 Hz.

Protection settings and coordination

Long-time pickup (Ir) adjusts from 0.4 to 1 x In across nine settings, with a corresponding delay (Tr) adjustable from 0.5 to 24 seconds at 6 x Ir. Instantaneous pickup (Ii) spans 1.5 to 10 x Ir, also in nine steps. This granularity lets you shape the trip curve to the load — motor starts, transformer inrush, or feeder protection — without swapping the unit. Zone selective interlocking (ZSI) is built in, so downstream faults clear at the closest breaker while upstream units hold — reduces arc-flash energy and keeps healthy feeders online. Thermal memory tracks the last 20 minutes of heating and cooling before and after a trip, preventing nuisance reclose on a still-hot conductor.

Drawout mounting and panel integration

The drawout mounting mode means this control unit slides into the EasyPact NW cradle — no hardwiring the trip unit itself. Physical footprint is 200 mm high, 55 mm wide, 75 mm deep. The digital display shows fault type (overload, short-circuit, earth fault, internal fault) and energy metering data, so a panel walk-down reads the event log without a laptop.

Frequently asked questions

What are the key protection functions of ENW21413?

The Trip System 2.0E provides LI protection: long-time overload and instantaneous short-circuit. It also indicates earth fault, internal fault, and short-circuit conditions on the digital display.

What is the trip unit rating range for ENW21413?

The adjustable trip unit rating covers 800 to 4000 A, with long-time pickup from 0.4 to 1 x In and instantaneous pickup from 1.5 to 10 x Ir.

Where can I buy ENW21413 and what is the lead time?

The ENW21413 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for the latest lead time.

What compliance documentation is available for ENW21413?

The unit is rated 690 V AC conforming to IEC 60947-2. For specific RoHS, REACH, or UL documentation, request the compliance package with your RFQ.

MPN
ENW21413