Schneider Electric ENW24101 — Air Circuit Breakers

ENW24101 EasyPact NW Circuit Breaker, 800 A, 50 kA

MPNENW24101
Active

Schneider Electric EasyPact NW ENW08N frame, circuit breaker, 3P, 800 A at 40 °C, 50 kA Icu at 440 V AC, drawout mount, IP40.

StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ENW24101 — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact NW
ApplicationDistribution

Electrical ratings

ENW24101 — Electrical ratings
ParameterValue
Rated current (In)800 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2

Breaking & withstand capacity

ENW24101 — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)50 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)105 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 88 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeN

Performance

ENW24101 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B

Mechanical & connection

ENW24101 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportRail
Contact position indicatorYes
Width441 mm
Height439 mm
Depth395 mm
Connection pitch115 mm without spreader
Connection locationRear

Environmental

ENW24101 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1

Approvals

ENW24101 — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

What this 800 A drawout breaker does for your main

The ENW24101 is a Schneider Electric EasyPact NW circuit breaker on the ENW08N frame — a three-pole, 800 A drawout unit built for distribution duty. That 800 A rating at 40 °C tells you it handles full continuous current in a warm switchroom without derating; push it to 60 °C and you'll need to knock the ampacity down per the thermal curve.

Drawout mount, rear connection — panel integration

Drawout mounting means the breaker slides into a cradle, so you can rack it out for maintenance or replacement without pulling the bus bars. Rear connection keeps the power cables out of the front of the panel — cleaner layout, less clutter for the guy wiring the control transformer. The 115 mm connection pitch without spreader sets the bus spacing; if you're retrofitting into an existing lineup, measure that pitch before ordering the adapter kit. IP40 keeps tools and fingers out but isn't rated for washdown — keep it indoors.

What the standards and durability numbers mean

Compliant with IEC 60947-2, the standard for low-voltage circuit breakers — that's the spec that defines the Icu, Ics, and Icw ratings, so you know the test protocol behind the numbers. Mechanical durability is 20,000 cycles with maintenance, 10,000 without; electrical durability is 6,000 cycles at 440 V without maintenance. That's not a daily-switch duty cycle — it's a main breaker that cycles on fault or maintenance, not a contactor running every minute.

Frequently asked questions

What is ENW24101's rated current and breaking capacity?

The ENW24101 is rated 800 A at 40 °C with a breaking capacity of 50 kA Icu at 220–440 V AC, conforming to IEC 60947-2.

Where can I buy ENW24101 and how is it quoted?

The ENW24101 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What compliance standards does ENW24101 meet?

The ENW24101 complies with IEC 60947-2 and IEC 60664-1 pollution degree 4, with suitability for isolation per IEC 60947-2.