Skip to main content
Schneider Electric ENW24142 — Air Circuit Breakers

Schneider Electric ENW24142 EasyPact NW Circuit Breaker, 100

MPNENW24142
Active

Schneider Electric EasyPact NW circuit breaker, ENW24142, 1000 A, 66 kA Icu, 3P, IP40, fixed mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ENW24142 — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact NW
ApplicationDistribution

Electrical ratings

ENW24142 — Electrical ratings
ParameterValue
Rated current (In)1000 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2

Breaking & withstand capacity

ENW24142 — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH

Performance

ENW24142 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B

Mechanical & connection

ENW24142 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeFixed
Mounting supportBase plate
Contact position indicatorYes
Width422 mm
Height352 mm
Depth297 mm
Connection pitch115 mm without spreader
Connection locationRear

Environmental

ENW24142 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1

Approvals

ENW24142 — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

What you're looking at

Schneider Electric ENW24142 is a fixed-mount EasyPact NW air circuit breaker rated 1000 A at 40 °C, 3-pole, with a 66 kA Icu breaking capacity at 220...440 V AC. The IP40 enclosure keeps tools and fingers out but isn't sealed against water; this lives in a dry switchgear lineup, not a washdown area.

Breaking capacity — the number that matters for fault coordination

That 1 kA gap between Icu and Ics is tight, typical of a high-performance air breaker. For selectivity studies, the Icw short-time withstand is 65 kA for 1 s at 440 V, so downstream breakers have time to clear before this one trips on a delayed curve.

The ENW24142 is current production. For a 1000 A frame breaker still in the catalog, the supply channel is standard.

Fixed mount on a base plate, rear-connected. The connection pitch is 115 mm without a spreader, so busbar drilling and cable lug spacing need to match that dimension. Horizontal or vertical connection position is allowed — useful for tight cabinet layouts. Dimensions: 422 mm wide, 352 mm high, 297 mm deep. That depth includes the rear connection space, so account for it in the enclosure depth.

Isolation and endurance

Electrical endurance at 440 V is 6,000 cycles without maintenance — enough for a distribution feeder that sees a few operations per year, not a motor-switching duty cycle.

Frequently asked questions

What is ENW24142's listed depth (297 mm) on this component line?

The depth is 297 mm, measured from the mounting base to the rear connection plane.

What is ENW24142's listed range (EasyPact) on this component line?

It belongs to the EasyPact NW range, Schneider's standard line of air circuit breakers for distribution applications.

What compliance documentation does this brand provide for ENW24142 (RoHS, REACH, UL, IEC)?

The breaker is certified to IEC 60947-2. For RoHS/REACH declarations and any UL listing, check the manufacturer's compliance documentation available via the product support portal.

MPN
ENW24142