Skip to main content
Schneider Electric ENW24157 — Air Circuit Breakers

Schneider Electric ENW24157 EasyPact NW Circuit Breaker, 800

MPNENW24157
Active

Schneider Electric EasyPact NW, circuit breaker, ENW24157, 800 A at 40 °C, 66 kA Icu at 440 V AC, 4 poles, IP40, fixed mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ENW24157 — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact NW
ApplicationDistribution

Electrical ratings

ENW24157 — Electrical ratings
ParameterValue
Rated current (In)800 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles4P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2

Breaking & withstand capacity

ENW24157 — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH

Performance

ENW24157 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B

Mechanical & connection

ENW24157 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeFixed
Mounting supportBase plate
Contact position indicatorYes
Width537 mm
Height352 mm
Depth297 mm
Neutral pole positionLeft
Connection pitch115 mm without spreader
Connection locationRear

Environmental

ENW24157 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1

Approvals

ENW24157 — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The Schneider Electric ENW24157 is a fixed-mount EasyPact NW air circuit breaker rated 800 A at 40 °C, built for distribution duty in industrial switchboards. It carries a 66 kA Icu at 220...440 V AC and 50 kA Icu at 690 V AC, both per IEC 60947-2, so it clears high fault currents without upstream coordination issues. The 4-pole design with left-side neutral and rear vertical/horizontal connections suits main or tie-breaker positions in low-voltage switchgear.

That 65 kA Ics / 66 kA Icu ratio (98 %) is high, typical of Category B breakers that are expected to remain in service after a fault. The 690 V operational voltage (Ue) and 1000 V insulation voltage (Ui) confirm it handles 690 V line-to-line systems common in heavy industrial plants.

Fixed mount on a base plate — no DIN rail, so panel cutouts and bolt patterns need to match the 537 mm width, 352 mm height, and 297 mm depth. Rear connection with a 115 mm connection pitch without spreader means busbar or cable terminations must follow that spacing. IP40 enclosure protection keeps out tools and fingers but not water; install inside a switchboard or enclosure rated for the environment. Pollution degree 4 per IEC 60664-1 means the breaker is designed for continuous conductive contamination (dust, condensation) — typical for unsealed industrial switchgear rooms.

Certified to IEC 60947-2 for low-voltage switchgear and controlgear. Isolation suitable per that standard — the breaker provides visible isolation when open. Pollution degree 4, ambient operation from -5 to 60 °C, storage from -40 to 85 °C. The 4 protected poles (4P 4d) with selectable neutral protection (no protection, 0.5× Ir, or 1× Ir) cover solidly-grounded and impedance-grounded systems.

Frequently asked questions

What is the breaking capacity of the ENW24157?

The ENW24157 has a 66 kA Icu at 220...440 V AC and 50 kA Icu at 690 V AC, both per IEC 60947-2. The service breaking capacity Ics is 65 kA at 440 V and 50 kA at 690 V.

Where can I buy the ENW24157?

The ENW24157 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What standards does the ENW24157 comply with?

The ENW24157 complies with IEC 60947-2 for low-voltage switchgear and is suitable for isolation per that standard. It is rated for pollution degree 4 per IEC 60664-1.

MPN