Schneider Electric EVS10H3MW20 — Air Circuit Breakers

Schneider Electric EVS10H3MW20 EasyPact EVS Circuit Breaker,

MPNEVS10H3MW20
Active

Schneider Electric EasyPact EVS, EVS10H3MW20, 3-pole drawout circuit breaker, 1000 A rated current, 65 kA breaking capacity at 440 V AC, IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EVS10H3MW20 — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact EVS
ApplicationDistribution
EVS10H3MW20 — Electrical ratings
ParameterValue
Rated current (In)1000 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2
EVS10H3MW20 — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
EVS10H3MW20 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 5000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B
EVS10H3MW20 — Mechanical & connection
ParameterValue
Control typeManually operated
Mounting modeDrawout
Mounting supportRail Base plate
Contact position indicatorYes
Width441 mm
Height439 mm
Depth395 mm
Connection pitch115 mm without spreader
Connection locationRear
EVS10H3MW20 — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1
EVS10H3MW20 — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

1000 A drawout breaker for distribution — EVS10H3MW20

Trip unit is the EVS Trip System2.0, electronic, with overload (long-time) and instantaneous short-circuit protection. Thermal memory holds for 20 minutes before and after tripping — meaning if a downstream fault heats the breaker and you reclose quickly, the trip curve remembers the thermal state and won't nuisance-trip on the next start. Pollution degree 4 (IEC 60664-1) confirms it's rated for industrial environments with conductive dust or condensation — no derating needed for dirty panel air.

Integration and deployment

Mounts on a rail base plate in a drawout configuration — rear-connected, with vertical or horizontal connection position. The 115 mm connection pitch (without spreader) matches standard bus-bar spacing for switchgear lineups. IP40 enclosure protection means it's fine inside a ventilated cabinet but not for washdown or outdoor exposure. Suitability for isolation is confirmed per IEC 60947-2, so it can serve as a visible-break disconnect in the distribution path.

Frequently asked questions

Where can I buy EVS10H3MW20 and get a price?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of EVS10H3MW20?

65 kA Icu at 220…440 V AC 50/60 Hz and 50 kA Icu at 690 V AC 50/60 Hz, both per IEC 60947-2.

What standards does EVS10H3MW20 comply with?

IEC 60947-2 for circuit breakers. Pollution degree 4 per IEC 60664-1. Suitability for isolation confirmed per IEC 60947-2.