Skip to main content
Schneider Electric EVS10H3MW20

Schneider Electric EVS10H3MW20 EasyPact EVS Circuit Breaker,

MPN EVS10H3MW20
Active

Schneider Electric EasyPact EVS, EVS10H3MW20, 3-pole drawout circuit breaker, 1000 A rated current, 65 kA breaking capacity at 440 V AC, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EVS10H3MW20 key specifications
ParameterValue
Control typeManually operated
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

EVS10H3MW20 additional specifications
ParameterValue
Temp operating min-5 °C
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width441 mm
Height439 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...70 °C

Product details

1000 A drawout breaker for distribution — EVS10H3MW20

Trip unit is the EVS Trip System2.0, electronic, with overload (long-time) and instantaneous short-circuit protection. Thermal memory holds for 20 minutes before and after tripping — meaning if a downstream fault heats the breaker and you reclose quickly, the trip curve remembers the thermal state and won't nuisance-trip on the next start. Pollution degree 4 (IEC 60664-1) confirms it's rated for industrial environments with conductive dust or condensation — no derating needed for dirty panel air.

Integration and deployment

Mounts on a rail base plate in a drawout configuration — rear-connected, with vertical or horizontal connection position. The 115 mm connection pitch (without spreader) matches standard bus-bar spacing for switchgear lineups. IP40 enclosure protection means it's fine inside a ventilated cabinet but not for washdown or outdoor exposure. Suitability for isolation is confirmed per IEC 60947-2, so it can serve as a visible-break disconnect in the distribution path.

MPN
EVS10H3MW20