Skip to main content
Schneider Electric EVS12H3MW60 — Air Circuit Breakers

Schneider Electric EVS12H3MW60 EasyPact EVS Circuit Breaker,

MPNEVS12H3MW60
Active

Schneider Electric EasyPact EVS, EVS12H3MW60, 3-pole drawout circuit breaker, 1250 A rated current, 65 kA breaking capacity at 440 V AC, electronic trip unit.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EVS12H3MW60 — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact EVS
ApplicationDistribution
EVS12H3MW60 — Electrical ratings
ParameterValue
Rated current (In)1250 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2
EVS12H3MW60 — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
EVS12H3MW60 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 5000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B
EVS12H3MW60 — Mechanical & connection
ParameterValue
Control typeManually operated
Mounting modeDrawout
Mounting supportRail Base plate
Contact position indicatorYes
Width441 mm
Height439 mm
Depth395 mm
Connection pitch115 mm without spreader
Connection locationRear
EVS12H3MW60 — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1
EVS12H3MW60 — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The Schneider Electric EVS12H3MW60 is a 3-pole drawout circuit breaker from the EasyPact EVS range, rated 1250 A at 40 °C with an electronic EVS Trip System6.0 trip unit. It provides overload (long-time), instantaneous short-circuit, short-time short-circuit, and earth-fault protection — four protection functions in one device, which means a single breaker covers feeder and fault protection without needing separate relays. Breaking capacity is 65 kA Icu at 220...440 V AC 50/60 Hz per IEC 60947-2, and 50 kA Icu at 690 V AC. The 25 ms maximum breaking time means the arc is quenched in under three line cycles at 50 Hz.

IP40 protection — suitable for indoor switchgear where large solids are excluded but not sealed against moisture. Pollution degree 4 per IEC 60664-1, meaning it's rated for continuous conductive contamination (dust, condensation), typical in industrial environments without climate control.

Category B utilization (IEC 60947-2) means this breaker is designed for selective coordination — it can hold a short-time delay to let downstream breakers clear a fault first, then trip itself if the fault persists. Electrical durability is 5000 cycles at 440/690 V without maintenance; mechanical durability is 10000 cycles without maintenance, 20000 with maintenance. That's a long service life for a main breaker in a distribution board that sees infrequent switching. That's a detail that matters for motor feeders or welder circuits with repetitive overload cycles.

Frequently asked questions

What are the key ratings of the EVS12H3MW60?

Rated current 1250 A at 40 °C, breaking capacity 65 kA Icu at 440 V AC and 50 kA at 690 V AC per IEC 60947-2. Electronic trip unit with overload, short-circuit, and earth-fault protection. Drawout mounting, 3-pole, IP40.

What compliance documentation does Schneider provide for the EVS12H3MW60?

The breaker is designed and tested to IEC 60947-2. It carries suitability for isolation per that standard. Specific RoHS, REACH, or UL documentation should be requested at quote time from the supplier.

MPN