Schneider Electric EVS40H3NW6A — Air Circuit Breakers

Schneider EVS40H3NW6A EasyPact EVS Circuit Breaker, 4000 A,

MPNEVS40H3NW6A
Active

Schneider Electric EasyPact EVS series, EVS40H3NW6A, 3-pole drawout circuit breaker, 4000 A rated current, 65 kA Icu at 440 V AC, electronically controlled with EVS Trip System6A.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EVS40H3NW6A — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact EVS
ApplicationDistribution
EVS40H3NW6A — Electrical ratings
ParameterValue
Rated current (In)4000 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2
EVS40H3NW6A — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
EVS40H3NW6A — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 5000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B
EVS40H3NW6A — Mechanical & connection
ParameterValue
Control typeElectrically operated
Mounting modeDrawout
Mounting supportRail Base plate
Contact position indicatorYes
Width441 mm
Height439 mm
Depth395 mm
Connection pitch115 mm without spreader
Connection locationRear
EVS40H3NW6A — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1
EVS40H3NW6A — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

Integrator note — EVS40H3NW6A

The Schneider Electric EVS40H3NW6A is a 3-pole drawout circuit breaker from the EasyPact EVS range, rated 4000 A at 40 °C and carrying a 65 kA Icu breaking capacity at 220…440 V AC 50/60 Hz per IEC 60947-2 (50 kA at 690 V AC). This is a Category B breaker — utilization class B per IEC 60947-2 — meaning it is designed for selectivity in distribution, with a deliberate short-time delay before tripping on a fault. The EVS Trip System6A electronic trip unit provides overload (long-time), instantaneous short-circuit, short-time short-circuit, and earth-fault protection. The drawout mounting (rail or base plate) allows the breaker to be racked out for maintenance without disturbing the rear-connected power cables. IP40 front-face protection suits indoor switchgear; pollution degree 4 per IEC 60664-1 means it tolerates conductive dust environments typical in heavy industrial distribution.

The 25 ms maximum breaking time means the arc is quenched within two cycles at 50 Hz, limiting let-through energy for downstream equipment. Thermal memory holds a 20-minute pre- and post-trip heat profile, so a reclose after a near-trip event will not falsely trip on a cold start — important for motor or transformer feeders where inrush repeats.

Panel integration & compliance

Dimensions: 441 mm wide × 439 mm high × 395 mm deep. Rear connection with a 115 mm pole pitch (without spreader). Vertical or horizontal connection positions give flexibility in busbar layout. The digital display on the trip unit shows fault cause (overload, short-circuit, earth fault, internal fault) for rapid troubleshooting. Mechanical durability is 20,000 cycles with maintenance, 10,000 without; electrical durability is 5,000 cycles at rated voltage without maintenance — figures that govern the breaker's service life in high-cycle applications like capacitor bank switching or motor starting.

Frequently asked questions

Where can I buy EVS40H3NW6A and what is the lead time?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of EVS40H3NW6A?

65 kA Icu at 220…440 V AC 50/60 Hz and 50 kA Icu at 690 V AC 50/60 Hz, both per IEC 60947-2.

What protection functions does the EVS Trip System6A provide?

Overload (long-time), instantaneous short-circuit, short-time short-circuit, and earth-fault protection.

Is EVS40H3NW6A suitable for isolation?

Yes, it is certified suitable for isolation per IEC 60947-2 and includes a contact position indicator.