Specifications

EZC100B3060 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZC100B3060 — Electrical
ParameterValue
Network type (AC/DC)AC DC
Rated current [In]60 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description3P
EZC100B3060 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]0.625 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 1.25 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 1.875 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 1.875 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeB
Trip unit technologyThermal-magnetic
Trip unit rating60 A at 50 °C
Trip unit nameTM-D
Protection typeOverload protection Short-circuit protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability13000 cycles
Local signallingPositive contact indication
EZC100B3060 — Mechanical
ParameterValue
Connection pitch25 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC100B
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width75 mm
Height130 mm
Depth60 mm
EZC100B3060 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZC100B3060 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 GB/T 14048.2 JIS C8201-2-2 EN/IEC 60947-2

Product details

The Schneider Electric EZC100B3060 is a 3-pole thermal-magnetic circuit breaker from the EasyPact EZC100B line, rated 60 A at 40 °C ambient. The TM-D trip unit handles overload and short-circuit protection — no earth-leakage module inside. It is a Category A breaker, meaning it is not specifically designed for high-frequency switching but for standard distribution protection. Breaking capacity varies by voltage: 10 kA Icu at 110–130 V AC, 10 kA at 220–240 V, 7.5 kA at 380–415 V, 5 kA at 440 V, and 2.5 kA at 550 V AC. The 5 kA at 440 V means this breaker is not a fit for heavy 480 V industrial mains where SCCR requirements exceed 10 kA; you would step up to the EZC250 or EZC400 frame for that. Rated insulation voltage (Ui) is 690 V AC, and rated operational voltage (Ue) is 550 V AC.

Mounts on a backplate with a fixed mounting mode. The connection pitch is 25 mm, and both upside and downside connections are front-facing. Dimensions: 75 mm wide, 130 mm high, 60 mm deep. Mechanical durability is rated at 13,000 cycles. That is standard for a molded-case breaker in this class — not a high-cycle switching device, but fine for a distribution panel where it operates a few times a year.

Frequently asked questions

What is the breaking capacity of the EZC100B3060 at 240 V?

The EZC100B3060 has a breaking capacity of 10 kA Icu at 220–240 V AC 50/60 Hz conforming to IEC 60947-2.

Where can I buy the EZC100B3060 and how is it quoted?

The EZC100B3060 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN