Schneider Electric EZC100B3060

Schneider Electric EZC100B3060 EasyPact EZC100B Circuit Brea

MPN EZC100B3060
Active

Schneider Electric EasyPact EZC100B, circuit breaker, EZC100B3060, 60 A, 3P, TM-D trip unit, 10 kA Icu at 240 V AC, IP20, backplate mount.

$41.14 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC100B3060 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage550 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch25 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C
Temp operating max70 °C

All specifications

EZC100B3060 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Depth60 mm
Width75 mm
Height130 mm
Mechanical life cycles13000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric EZC100B3060 is a 3-pole thermal-magnetic circuit breaker from the EasyPact EZC100B line, rated 60 A at 40 °C ambient. The TM-D trip unit handles overload and short-circuit protection — no earth-leakage module inside. It is a Category A breaker, meaning it is not specifically designed for high-frequency switching but for standard distribution protection. Breaking capacity varies by voltage: 10 kA Icu at 110–130 V AC, 10 kA at 220–240 V, 7.5 kA at 380–415 V, 5 kA at 440 V, and 2.5 kA at 550 V AC. The 5 kA at 440 V means this breaker is not a fit for heavy 480 V industrial mains where SCCR requirements exceed 10 kA; you would step up to the EZC250 or EZC400 frame for that. Rated insulation voltage (Ui) is 690 V AC, and rated operational voltage (Ue) is 550 V AC.

Mounts on a backplate with a fixed mounting mode. The connection pitch is 25 mm, and both upside and downside connections are front-facing. Dimensions: 75 mm wide, 130 mm high, 60 mm deep. Mechanical durability is rated at 13,000 cycles. That is standard for a molded-case breaker in this class — not a high-cycle switching device, but fine for a distribution panel where it operates a few times a year.

MPN