Schneider Electric EasyPact EZC100H, EZC100H2050, thermal-magnetic circuit breaker, 50 A, 2 poles, 10–100 kA breaking capacity, IP20, IK07.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

EZC100H2050 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZC100H2050 — Electrical
ParameterValue
Network type (AC/DC)DC AC
Rated current [In]50 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description2P
EZC100H2050 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 50 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
Trip unit technologyThermal-magnetic
Trip unit rating50 A at 50 °C
Trip unit nameTM-D
Protection typeShort-circuit protection Overload protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability13000 cycles
Local signallingPositive contact indication
EZC100H2050 — Mechanical
ParameterValue
Connection pitch25 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC100H
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width50 mm
Height130 mm
Depth60 mm
EZC100H2050 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZC100H2050 — Approvals
ParameterValue
StandardsJIS C8201-2-2 EN/IEC 60947-1 GB/T 14048.2 EN/IEC 60947-2

Product details

The EZC100H2050 is a 2-pole thermal-magnetic circuit breaker from the Schneider Electric EasyPact EZC100H series, rated 50 A at 40 °C. The TM-D trip unit provides short-circuit and overload protection. The H breaking capacity code means it delivers 10 kA Icu at 550 V AC, 30 kA at 400–415 V AC, and 50 kA at 220–240 V AC — so it can interrupt fault currents up to those levels without upstream coordination issues. For DC circuits, it breaks 10 kA at 125 V DC (1P) or 250 V DC (2P). The 690 V AC rated insulation voltage and Category A utilization confirm it is designed for distribution panelboard duty, not motor-starting cycles. IP20 finger-safe terminals and IK07 impact resistance suit it for backplate mounting in a locked panel.

Deployment context

Mounts fixed to a backplate with front-front connections at a 25 mm pitch. The toggle control provides positive contact indication — the handle position shows whether the contacts are open or closed, which aids troubleshooting during commissioning.

Designed to EN/IEC 60947-1 and EN/IEC 60947-2, plus JIS C8201-2-2 and GB/T 14048.2. No earth-leakage protection is integrated; the neutral pole is unprotected. The 13,000-cycle mechanical durability is typical for distribution breakers — not a high-cycle motor-switching device.

Frequently asked questions

What is the breaking capacity of EZC100H2050 at 400 V AC?

30 kA Icu at 400–415 V AC 50/60 Hz per IEC 60947-2. At 440 V AC it drops to 20 kA, and at 550 V AC to 10 kA.

Where can I buy EZC100H2050 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock figures are published here.

What compliance documentation does Schneider provide for EZC100H2050?

The breaker is designed to EN/IEC 60947-1 and EN/IEC 60947-2, JIS C8201-2-2, and GB/T 14048.2. It carries IP20 and IK07 ratings. For RoHS/REACH declarations, refer to the manufacturer's product environmental profile.