Schneider Electric EZC250H3125 — Circuit Breaker Accessories

Schneider Electric EZC250H3125 EasyPact EZC250H Circuit Brea

MPNEZC250H3125
Active

Schneider Electric EasyPact EZC250H series, EZC250H3125, 3-pole circuit breaker, 125 A rated current, thermal-magnetic TM-D trip unit, 36 kA breaking capacity at 415 V AC, IP20, backplate mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

EZC250H3125 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZC250H3125 — Electrical
ParameterValue
Network type (AC/DC)DC AC
Rated current [In]125 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description3P
EZC250H3125 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 18 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
Trip unit technologyThermal-magnetic
Trip unit rating125 A at 50 °C
Trip unit nameTM-D
Protection typeShort-circuit protection Overload protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability10000 cycles
Local signallingPositive contact indication
EZC250H3125 — Mechanical
ParameterValue
Connection pitch35 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC250H
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width105 mm
Height165 mm
Depth60 mm
EZC250H3125 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZC250H3125 — Approvals
ParameterValue
StandardsGB/T 14048.2 EN/IEC 60947-2 JIS C8201-2-2 EN/IEC 60947-1

Product details

The EZC250H3125 is a 3-pole thermal-magnetic circuit breaker from Schneider Electric's EasyPact EZC250H line, rated 125 A at 40 °C and 125 A at 50 °C — the lower ambient derates the trip unit, so a 125 A continuous load at 50 °C needs the next frame up. The TM-D trip unit provides short-circuit and overload protection with a fixed thermal and magnetic curve, no adjustment. Breaking capacity varies by voltage: 36 kA Icu at 400–415 V AC is the figure most panel builders will check for 400 V distribution — it tells you the breaker can safely clear a fault up to 36 kA without welding contacts or rupturing the case. For DC circuits, it delivers 30 kA Icu at 125 V DC (1-pole) and 30 kA Icu at 250 V DC (2-pole). IK07 means it survives a 2 J impact, typical for switchgear handling.

This breaker mounts to a backplate with fixed mounting — not DIN rail, so plan for screw-down lugs or a dedicated mounting bracket. Both line and load connections are front-facing, so busbar or cable routing stays on one plane — useful for stacked breaker layouts. Connection pitch is 35 mm, which matches standard busbar spacing for 3-pole breakers. The toggle control gives positive contact indication — you can see the contact position through the front window. Mechanical durability is 10,000 cycles — fine for distribution, not for frequent switching duty.

The breaker is certified to GB/T 14048.2, EN/IEC 60947-2, and JIS C8201-2-2. Network frequency is 50/60 Hz. The device is designed for distribution applications.

Frequently asked questions

Where can I buy EZC250H3125 and get a price?

The EZC250H3125 is sourced to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing — stock and price are confirmed at quote time.

What is the breaking capacity of EZC250H3125 at 415 V AC?

At 400–415 V AC, the EZC250H3125 provides 36 kA Icu. This is the value most panel builders use for 400 V distribution systems. At 550 V AC it drops to 10 kA Icu.

Does EZC250H3125 include earth-leakage protection?

No, the EZC250H3125 does not include earth-leakage protection. It provides only short-circuit and overload protection via the thermal-magnetic TM-D trip unit. Add an external Vigi module or RCD if ground-fault detection is required.

MPN
EZC250H3125