Schneider Electric EasyPact EZC250H, 3-pole MCCB, 200 A rated at 40 °C, TM-D thermal-magnetic trip unit, breaking capacity 10-85 kA depending on voltage, IEC 60947-2.

$157.86Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

EZC250H3200 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZC250H3200 — Electrical
ParameterValue
Network type (AC/DC)AC DC
Rated current [In]200 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description3P
EZC250H3200 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 18 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
Trip unit technologyThermal-magnetic
Trip unit rating200 A at 50 °C
Trip unit nameTM-D
Protection typeOverload protection Short-circuit protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability10000 cycles
Local signallingPositive contact indication
EZC250H3200 — Mechanical
ParameterValue
Connection pitch35 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC250H
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width105 mm
Height165 mm
Depth60 mm
EZC250H3200 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZC250H3200 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 GB/T 14048.2 EN/IEC 60947-2

Product details

The EZC250H3200 is a 3-pole moulded-case circuit breaker from the Schneider EasyPact series, rated 200 A at 40 °C ambient (derated to 200 A at 50 °C per the TM-D trip unit curve). Breaking capacity varies with system voltage: 85 kA at 240 V AC, 36 kA at 415 V AC, and 10 kA at 550 V AC. That 10 kA at 550 V is the limiting case for a 480 V line-to-line system; the 36 kA at 415 V covers most European 400 V panels. The part is utilisation category A, meaning it is not intended for frequent switching under load — it is a distribution breaker, not a motor-starter disconnect. Mounting is fixed (backplate), not DIN-rail, so plan for a dedicated panel footprint. The front-connection terminals (upside and downside) accept cable lugs at a 35 mm pitch. IP20 finger-safe on the front face; IK07 impact rating means it withstands a 2 J hammer blow, adequate for a locked panel. The toggle handle gives positive contact indication — you can visually confirm the contact position without removing the cover. No earth-leakage or neutral protection built in; this is a straight 3-pole breaker with three protected poles and no neutral pole.

The IEC 60947-2 certification covers the breaking capacity claims, isolation suitability, and pollution degree 3 rating.

Frequently asked questions

Where can I buy EZC250H3200 and how is it quoted?

The part is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — no stock count or lead-time figure is published here, but the supply channel is open and quoted on request.

What is the breaking capacity of EZC250H3200 at 400 V?

At 400–415 V AC 50/60 Hz, the Icu is 36 kA per IEC 60947-2. At 440 V it drops to 25 kA, and at 550 V to 10 kA. The 36 kA at 400 V covers most European distribution panels.

Does EZC250H3200 include earth-leakage protection?

No. The TM-D trip unit provides only thermal-magnetic overload and short-circuit protection. Earth-leakage protection is not built in — specify a separate RCD or a breaker with a Vigi add-on if required.

What compliance documentation is available for EZC250H3200?

The breaker carries IEC 60947-2 certification, which covers the breaking capacity, isolation suitability, and pollution degree 3 rating. It also meets GB/T 14048.2 for China. RoHS and REACH compliance are standard for the EasyPact series, though not explicitly listed in the spec record.