Skip to main content
Schneider Electric EZC400N4400N — Circuit Breaker Accessories

Schneider Electric EZC400N4400N EasyPact EZC400N, 400 A, 36

MPNEZC400N4400N
Active

Schneider Electric EasyPact EZC400N, circuit breaker, 400 A thermal-magnetic TM-D trip, 4-pole, 36 kA Icu at 440 V AC, IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

EZC400N4400N — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZC400N4400N — Electrical
ParameterValue
Network type (AC/DC)AC
Rated current [In]400 A at 40 °C
Rated operational voltage [Ue]440 V AC 50/60 Hz conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description4P
EZC400N4400N — Protection & Performance
ParameterValue
Breaking capacity36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]18 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 20 kA at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeN
Trip unit technologyThermal-magnetic
Trip unit rating400 A at 50 °C
Trip unit nameTM-D
Protection typeOverload protection Short-circuit protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability10000 cycles
Electrical durabilityCategory A: 4000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
Local signallingPositive contact indication
Contact position indicatorYes
EZC400N4400N — Mechanical
ParameterValue
Connection pitch45 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC400N
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width140 mm
Height255 mm
Depth140 mm
ColourBlack
EZC400N4400N — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to EN 50102
Pollution degree3 conforming to IEC 60947
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZC400N4400N — Approvals
ParameterValue
StandardsGB/T 14048.2 EN/IEC 60947-2 JIS C8201-2-2 EN/IEC 60947-1

Product details

The headline breaking capacity is 36 kA Icu at 440 V AC 50/60 Hz per IEC 60947-2, with a higher 40 kA Icu available at 220/230 V AC. The TM-D trip gives you fixed thermal (overload) and magnetic (short-circuit) protection curves; magnetic pickup is set at 4000 A, so it clears hard faults fast while riding through motor inrush.

Standards and approvals — what they certify

This breaker carries compliance with EN/IEC 60947-2 (the main standard for low-voltage switchgear and controlgear), plus GB/T 14048.2 (Chinese national standard) and JIS C8201-2-2 (Japanese industrial standard). That triple certification covers most global project specs without a separate variant. It is also certified for isolation per IEC 60947-2 — meaning you can safely use it as a visible-break disconnect for lockout-tagout, provided the positive contact indication on the toggle matches the actual contact state. Pollution degree 3 (conforming to IEC 60947) means it's rated for the conductive dust and humidity typical in industrial enclosures, not just clean control rooms.

Fixed-mount via backplate with front-front connections — both line and load terminate on the front face, which simplifies busbar routing in a distribution panel but means you need clearance for cable bending radius on both sides. The 45 mm pole pitch matches standard Schneider EasyPact busbar systems. IP20 finger-safe protection on the front; IK07 impact rating means it survives a 2 J hammer blow (typical for panel-door mounting).

Frequently asked questions

What is the breaking capacity of EZC400N4400N at 440 V?

The breaking capacity is 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2. At 220/230 V AC it rises to 40 kA Icu.

What standards does the EZC400N4400N comply with?

It complies with EN/IEC 60947-2, GB/T 14048.2, and JIS C8201-2-2, covering international, Chinese, and Japanese installation standards.

Where can I buy EZC400N4400N and how is it quoted?

EZC400N4400N is sourced to order through independent distribution channels. Submit an RFQ for current pricing and availability — confirmed at quote time, not a published figure.

MPN