Skip to main content
Schneider Electric EZCV250N4100 — Circuit Breaker Accessories

Schneider Electric EZCV250N4100 EasyPact EZCV250N, 100 A, 20

MPNEZCV250N4100
Obsolete

Schneider Electric EasyPact EZCV250N, EZCV250N4100, 4-pole circuit breaker, 100 A at 40 °C, 20 kA Icu at 440 V AC, thermal-magnetic TM-D trip unit with earth-leakage protection.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EZCV250N4100 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZCV250N4100 — Electrical
ParameterValue
Network type (AC/DC)AC
Rated current [In]100 A at 40 °C
Rated operational voltage [Ue]440 V AC 50/60 Hz conforming to IEC 60947-2
Rated insulation voltage [Ui]440 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description4P
EZCV250N4100 — Protection & Performance
ParameterValue
Breaking capacity20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeN
Trip unit technologyThermal-magnetic
Trip unit rating100 A at 40 °C
Trip unit nameTM-D
Protection typeShort-circuit protection Earth-leakage protection Overload protection
Earth-leakage protectionWith
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability10000 cycles
Local signallingPositive contact indication
EZCV250N4100 — Mechanical
ParameterValue
Connection pitch35 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZCV250N
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width140 mm
Height165 mm
Depth68 mm
EZCV250N4100 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to EN 50102
Pollution degree3 conforming to IEC 60947
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZCV250N4100 — Approvals
ParameterValue
StandardsGB/T 14048.2 EN/IEC 60947-1 JIS C8201-2-2 EN/IEC 60947-2

Product details

The Schneider Electric EZCV250N4100 is a 4-pole EasyPact EZCV250N circuit breaker rated 100 A at 40 °C with a thermal-magnetic TM-D trip unit. Earth-leakage protection is built in, so this breaker handles both overload/short-circuit and ground-fault detection in one package — no separate RCD module needed. That saves a DIN slot and simplifies wiring in a panel where you need both functions on a feeder. The 4-pole design with 3 protected poles and no neutral protection is typical for a 3-phase + N distribution board where the neutral is solidly bonded and doesn't need its own trip element. Mounts fixed to a backplate with front connections top and bottom — standard for panel builders wiring a fixed distribution section.

Where it goes and what it guards

This breaker is designed for distribution duty in AC networks at 50/60 Hz. The TM-D trip unit gives a fixed thermal curve for overload and a fixed magnetic threshold for short-circuit — no adjustment dials. That's fine for a dedicated feeder where the load is known and won't change. For a motor circuit that needs adjustable overloads, you'd look at a different trip technology; this one is for straightforward cable and busbar protection.

Frequently asked questions

What is the breaking capacity of EZCV250N4100 at 440 V?

20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2. That's the maximum fault current it can safely interrupt at that voltage level.

What protection functions does this breaker include?

Short-circuit protection, overload protection, and earth-leakage protection. The thermal-magnetic TM-D trip unit handles the first two; the earth-leakage function is integrated into the same housing.

What compliance standards does EZCV250N4100 meet?

It conforms to GB/T 14048.2, EN/IEC 60947-1, JIS C8201-2-2, and EN/IEC 60947-2. It also carries an IK07 impact rating (EN 50102) and IP20 finger protection (IEC 60529).

MPN
EZCV250N4100