Schneider Electric EZCV250N4100

Schneider Electric EZCV250N4100 EasyPact EZCV250N, 100 A, 20

MPN EZCV250N4100
Obsolete

Schneider Electric EasyPact EZCV250N, EZCV250N4100, 4-pole circuit breaker, 100 A at 40 °C, 20 kA Icu at 440 V AC, thermal-magnetic TM-D trip unit with earth-leakage protection.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZCV250N4100 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui440 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C

All specifications

EZCV250N4100 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
Depth68 mm
Width140 mm
Height165 mm
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric EZCV250N4100 is a 4-pole EasyPact EZCV250N circuit breaker rated 100 A at 40 °C with a thermal-magnetic TM-D trip unit. Earth-leakage protection is built in, so this breaker handles both overload/short-circuit and ground-fault detection in one package — no separate RCD module needed. That saves a DIN slot and simplifies wiring in a panel where you need both functions on a feeder. The 4-pole design with 3 protected poles and no neutral protection is typical for a 3-phase + N distribution board where the neutral is solidly bonded and doesn't need its own trip element. Mounts fixed to a backplate with front connections top and bottom — standard for panel builders wiring a fixed distribution section.

Where it goes and what it guards

This breaker is designed for distribution duty in AC networks at 50/60 Hz. The TM-D trip unit gives a fixed thermal curve for overload and a fixed magnetic threshold for short-circuit — no adjustment dials. That's fine for a dedicated feeder where the load is known and won't change. For a motor circuit that needs adjustable overloads, you'd look at a different trip technology; this one is for straightforward cable and busbar protection.

MPN
EZCV250N4100