Skip to main content
Schneider Electric LA4DFE — Reversing Contactors

TeSys LA4DFE interface module, 48 V DC / 250 V AC

MPNLA4DFE
Active

Schneider Electric TeSys D LA4DFE interface amplifier module, relay output, 48 V DC control / 250 V AC switching, top-mounted on contactor.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LA4DFE — Identification
ParameterValue
Product rangeTeSys
Device short nameLA4D
Product or component typeInterface module
LA4DFE — Electrical
ParameterValue
Rated operational voltage [Ue]Control circuit 24...250 V AC
Control circuit voltage limits33...60 V at 68 °F (20 °C)
Rated insulation voltage [Ui]250 V - control circuit IEC 60947-5-1
LA4DFE — Motor & Load
ParameterValue
Number of poles3P
LA4DFE — Switching & Durability
ParameterValue
Electrical durability10 Mcycles 240 V
LA4DFE — Communication & I/O
ParameterValue
Current consumption15 mA 68 °F (20 °C)
LA4DFE — Mechanical
ParameterValue
Connections / terminalsControl circuit connector 1 0.002...0.004 in² (1...2.5 mm²)flexible with cable end Control circuit connector 1 0.002...0.004 in² (1...2.5 mm²)flexible without cable end Control circuit connector 1 0.002...0.004 in² (1...2.5 mm²)solid with cable end Control circuit connector 1 0.002...0.004 in² (1...2.5 mm²)solid without cable end Control circuit connector 2 0.002...0.004 in² (1...2.5 mm²)flexible with cable end Control circuit connector 2 0.002...0.004 in² (1...2.5 mm²)flexible without cable end Control circuit connector 2 0.002...0.004 in² (1...2.5 mm²)solid with cable end Control circuit connector 2 0.002...0.004 in² (1...2.5 mm²)solid without cable end
Height0.5 in (12 mm)
LA4DFE — Environmental
ParameterValue
Operating ambient temperature-13...131 °F (-25...55 °C)
Storage ambient temperature-40...176 °F (-40...80 °C)
IP degree of protectionIP2X conforming to VDE 0106
Protective treatmentTH IEC 60068
LA4DFE — Approvals
ParameterValue
StandardsIEC 60255-5
LA4DFE — Specifications
ParameterValue
Protection typeBuilt-in by diode

Product details

The Schneider Electric TeSys D LA4DFE is an interface amplifier module that sits between a low-level DC control signal and a contactor coil. It accepts a 48 V DC control supply and switches up to 250 V AC on the output side, letting a PLC or safety relay with a limited DC output drive a standard AC contactor coil. The module top-mounts directly onto a TeSys D contactor — no additional DIN-rail footprint needed. The built-in diode provides coil suppression, and an LED gives local status indication.

Control voltage limits span 33...60 V DC at 20 °C, so a nominal 48 V DC supply with typical ±10 % tolerance (43.2...52.8 V) sits comfortably inside the window. The module draws 15 mA from that supply. State 0 is guaranteed at ≤ 1.3 mA and < 4.8 V, which means most PLC digital outputs with a low-side leakage under 2 mA will reliably turn the module off. On the output side, the rated operational voltage covers 24...250 V AC. The insulation voltage is rated 250 V per IEC 60947-5-1, so the module is sized for standard 240 V control circuits.

Installation notes

Top-mounts onto the contactor — no DIN rail consumed. The IP2X finger protection (VDE 0106) is typical for enclosed panel gear; not rated for washdown. Heat dissipation is 0.6 W on the control circuit — negligible for panel thermal budgeting. Ambient operating range is -25...55 °C, storage -40...80 °C. The TH protective treatment per IEC 60068 covers tropicalized environments.

Frequently asked questions

What is the closest alternative to LA4DFE in the TeSys D family?

Within the TeSys D interface module range, the LA4DFE is the 48 V DC control variant. The LA4DA is the 24 V DC version and the LA4DB is 110 V DC. Pinout and mounting are identical; the control voltage limits differ. Choose based on your PLC output voltage.

What compliance documentation does Schneider provide for LA4DFE?

The module is designed to IEC 60255-5 (measuring relays and protection equipment) and IEC 60947-5-1 (control circuit devices). The TH protective treatment follows IEC 60068. Standard Schneider declarations for CE, UKCA, and RoHS apply to the TeSys D range.

MPN
LA4DFE