Schneider Electric LC3F225U7 — Contactors

Schneider Electric LC3F225U7 TeSys F Star Delta Starter, 100

MPNLC3F225U7
Active

Schneider Electric TeSys F LC3F225U7 pre-wired star delta starter, 3 x 3P, AC-3, 100…220 kW motor power, 240 V AC 50/60 Hz coil.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LC3F225U7 — Identification
ParameterValue
Product / component typeStar delta starter
Series / rangeTeSys
ApplicationMotor control
LC3F225U7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit <= 1000 V AC 16 Hz 2/3...200 Hz
Utilisation categoryAC-3
LC3F225U7 — Contacts & Poles
ParameterValue
Pole configuration3 x 3P
LC3F225U7 — Environmental
ParameterValue
IP degree of protectionIP20 front face with shrouds IEC 60529 IP20 front face with shrouds VDE 0106
Operating altitude9842.52 ft (3000 m) without derating
Mechanical robustnessVibrations contactor open2 Gn, 5...300 Hz Shocks contactor closed15 Gn for 11 ms Vibrations contactor closed5 Gn, 5...300 Hz Shocks contactor open7 Gn for 11 ms
Protective treatment / pollution degreeTH
LC3F225U7 — Approvals
ParameterValue
StandardsEN 60947-4-1 EN 60947-1 IEC 60947-1 JIS C8201-4-1 IEC 60947-4-1
LC3F225U7 — Mechanical
ParameterValue
Width20.7 in (525 mm)
Height4.3 in (110 mm)
Depth9.3 in (235 mm)

Product details

The Schneider Electric LC3F225U7 is a pre-wired star delta starter from the TeSys F series, designed for three-phase motor starting where reduced inrush current is needed — typically pumps, fans, compressors, and conveyors on a plate-mounted installation. Rated AC-3 (motor switching), it handles 100 kW at 220/230 V, 200 kW at 380/400 V and 415 V, and 220 kW at 440 V — all 50/60 Hz. The 240 V AC control coil pulls 805 VA inrush at 50 Hz, 970 VA at 60 Hz. The unit integrates three contactors (star, line, delta) with a built-in timing relay providing a 20 s starting time and operating times of 20…35 ms closing, 7…15 ms opening. Auxiliary contacts are pre-configured: 1 NC + 1 NO on the star contactor, 2 NC + 1 NO on line, 1 NC + 2 NO on delta.

AC-3 utilisation category means the starter is rated for switching squirrel-cage motors — making and breaking stalled-rotor currents during start, then carrying full-load current. The 2250 A making capacity (IEC 60947-4-1) and 1800 A breaking capacity tell you it can close onto and interrupt a locked-rotor condition without welding or excessive arcing. Rated insulation voltage is 1000 V per IEC 60947-4-1, 1500 V per VDE 0110 Group C — so it is safe for 690 V systems with margin. The associated fuse recommendation of 315 A gG or 250 A aM (up to 440 V) gives a coordination starting point for branch circuit protection. Mechanical durability is 10 Mcycles; maximum operating rate is 2400 cycles per hour at 55 °C.

Physical integration and wiring

Plate-mounted unit measuring 20.7 in wide × 4.3 in high × 9.3 in deep (525 × 110 × 235 mm). Power connections are bolted — M10 bolts, bar or ring terminals up to 185 mm². Control wiring uses screw clamp terminals accepting 1…4 mm² flexible with ferrule, or solid. Tightening torque: 35 N·m on the power circuit, 1.2 N·m on control. No DIN-rail mounting — this is a plate/frame install, typical for a motor control centre bucket or a dedicated backplate.

Standards compliance covers EN/IEC 60947-4-1 and 60947-1, plus JIS C8201-4-1 — accepted across European, IEC, and Japanese markets. The protective treatment is TH (tropicalised), suitable for humid environments.

Frequently asked questions

What motor power range does this star delta starter cover?

It covers 100 kW at 220/230 V AC, 200 kW at 380/400 V and 415 V AC, and 220 kW at 440 V AC — all 50/60 Hz, AC-3 duty.

What is the control voltage and coil inrush?

The control circuit is 240 V AC 50/60 Hz. Inrush power is 805 VA at 50 Hz and 970 VA at 60 Hz (cos φ 0.3 at 20 °C).

What are the physical dimensions of the LC3F225U7?

Width 20.7 in (525 mm), height 4.3 in (110 mm), depth 9.3 in (235 mm). Plate-mounted, not DIN rail.

What fuse rating is recommended for branch circuit protection?

315 A gG or 250 A aM up to 440 V. This provides a coordination baseline for the starter's making and breaking capacities.