Skip to main content
Schneider Electric LC3F225U7A64 — Contactors

Schneider TeSys F LC3F225U7A64 Star Delta Starter, 225 A AC-

MPNLC3F225U7A64
Obsolete

Schneider Electric TeSys F LC3F225U7A64, pre-wired star delta starter, 225 A AC-3 rated operational current at ≤440 V, 240 V AC 50/60 Hz control circuit.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC3F225U7A64 — Identification
ParameterValue
Product / component typeStar delta starter
Series / rangeTeSys
ApplicationMotor control
LC3F225U7A64 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: <= 1000 V AC 16 Hz 2/3...200 Hz
Utilisation categoryAC-3
LC3F225U7A64 — Contacts & Poles
ParameterValue
Pole configuration3 x 3P
LC3F225U7A64 — Environmental
ParameterValue
IP degree of protectionIP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Vibrations contactor closed: 5 Gn, 5...300 Hz Shocks contactor open: 7 Gn for 11 ms
Protective treatment / pollution degreeTH
LC3F225U7A64 — Approvals
ParameterValue
StandardsEN 60947-1 EN 60947-4-1 IEC 60947-4-1 IEC 60947-1 JIS C8201-4-1
LC3F225U7A64 — Mechanical
ParameterValue
Width525 mm
Height110 mm
Depth235 mm

Product details

The Schneider TeSys F LC3F225U7A64 is a pre-wired star delta starter designed for motor control in the AC-3 utilisation category — the standard duty for squirrel-cage induction motors during starting and running. It carries a rated operational current of 225 A at ≤440 V AC, which translates to motor power ratings of 100 kW at 220/230 V, 200 kW at 380/400 V, 200 kW at 415 V, and 220 kW at 440 V, all at 50/60 Hz. The unit is pre-wired with three power poles (3 x 3 NO) and includes auxiliary contacts: 1 NC and 1 NO for the KM1 star contactor, 2 NC and 1 NO for KM2 line, and 1 NC and 2 NO for KM3 delta. Control circuit voltage is 240 V AC at 50/60 Hz, with an operational range of 0.85 to 1.1 Uc and drop-out between 0.35 and 0.55 Uc.

For a 200 kW motor at 400 V, that's the operating point this part is sized for. The rated making capacity is 2250 A (IEC 60947-4-1), and the breaking capacity is 1800 A, so it can handle the inrush and fault-clearing demands of that motor class. The heat dissipation range of 18 to 24 W gives the panel designer a figure for thermal management inside the enclosure.

Mounting is plate-based (not DIN rail), so plan for a dedicated backplate or mounting panel. Dimensions are 525 mm wide, 110 mm high, and 235 mm deep — a substantial footprint that needs clear access for the power circuit bolted connections (M10 bolts) and busbar cross-section of 32 x 4 mm. Power circuit terminals accept lugs or ring terminals up to 185 mm²; control circuit uses screw clamp terminals accepting 1 to 4 mm² flexible or solid wire. The TH protective treatment indicates a tropicalized coating for humidity and corrosion resistance.

The starter complies with EN 60947-1, EN 60947-4-1, IEC 60947-4-1, IEC 60947-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C.

Frequently asked questions

What is the depth of the LC3F225U7A64?

The depth is 235 mm.

What is the range of the LC3F225U7A64?

It belongs to the TeSys range, specifically the TeSys F product series.

MPN
LC3F225U7A64