Schneider Electric LC3F225V7 — Contactors

TeSys F LC3F225V7 Star Delta Starter, 225 A AC-3, 400 V AC C

MPNLC3F225V7
Obsolete

Schneider Electric TeSys F LC3F225V7, star delta starter, 225 A AC-3, 400 V AC 50/60 Hz coil, 200 kW at 380/400 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC3F225V7 — Identification
ParameterValue
Product / component typeStar delta starter
Series / rangeTeSys
ApplicationMotor control
LC3F225V7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: <= 1000 V AC 16 Hz 2/3...200 Hz
Utilisation categoryAC-3
LC3F225V7 — Contacts & Poles
ParameterValue
Pole configuration3 x 3P
LC3F225V7 — Environmental
ParameterValue
IP degree of protectionIP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Vibrations contactor closed: 5 Gn, 5...300 Hz Shocks contactor open: 7 Gn for 11 ms
Protective treatment / pollution degreeTH
LC3F225V7 — Approvals
ParameterValue
StandardsIEC 60947-4-1 EN 60947-4-1 EN 60947-1 IEC 60947-1 JIS C8201-4-1
LC3F225V7 — Mechanical
ParameterValue
Width525 mm
Height110 mm
Depth235 mm

Product details

The LC3F225V7 is a pre-wired TeSys F star delta starter from Schneider Electric, built for motor control in the 200 kW range at 400 V. It's rated 225 A AC-3 (switching motor loads), with a 400 V AC 50/60 Hz control coil. The assembly includes three 3-pole contactors (KM1 star, KM2 line, KM3 delta) with auxiliary contacts already wired: 1 NC + 1 NO on the star, 2 NC + 1 NO on line, 1 NC + 2 NO on delta. That saves panel wiring time — just land the motor and control power.

The 225 A rated operational current (Ie) at ≤ 440 V AC in AC-3 category means it's sized for squirrel-cage motor starting — the category that defines making and breaking under starting current. That 225 A is the full-load motor current it handles, not a resistive-heater rating. Motor power tables confirm the range: 100 kW at 230 V, 200 kW at 400/415 V, 220 kW at 440 V. The 400 V coil (Uc) pulls 805 VA inrush at 50 Hz, 970 VA at 60 Hz — plan your control transformer accordingly. Rated making capacity is 2250 A, breaking capacity 1800 A, both per IEC 60947-4-1, so it handles the transient during a star-to-delta transition without welding contacts.

This is a plate-mount starter — no DIN rail. The form factor is 525 mm wide, 235 mm deep, 110 mm high, with M10 power connections accepting busbars up to 32 x 4 mm or lugs up to 185 mm². Control wiring uses screw clamp terminals (1 to 4 mm² flexible). The pre-wired auxiliary contacts reduce the risk of mis-wiring the interlock logic that keeps star and delta from closing simultaneously.

Frequently asked questions

What are the motor power ratings for this starter?

It delivers 100 kW at 220/230 V AC, 200 kW at 380/400 V and 415 V AC, and 220 kW at 440 V AC, all at 50/60 Hz.

What is the control coil voltage and inrush?

The coil is rated 400 V AC 50/60 Hz, with an inrush of 805 VA at 50 Hz (cos φ 0.3) and 970 VA at 60 Hz (cos φ 0.3).