Schneider TeSys F LC3F225V7A64 Star Delta Starter, 225 A AC-

MPNLC3F225V7A64
Obsolete

Schneider Electric TeSys F LC3F225V7A64, pre-wired star delta starter, 225 A rated operational current at ≤440 V AC AC-3, 400 V AC 50/60 Hz control coil, plate mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC3F225V7A64 — Identification
ParameterValue
Product / component typeStar delta starter
Series / rangeTeSys
ApplicationMotor control
LC3F225V7A64 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: <= 1000 V AC 16 Hz 2/3...200 Hz
Utilisation categoryAC-3
LC3F225V7A64 — Contacts & Poles
ParameterValue
Pole configuration3 x 3P
LC3F225V7A64 — Environmental
ParameterValue
IP degree of protectionIP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Vibrations contactor closed: 5 Gn, 5...300 Hz Shocks contactor open: 7 Gn for 11 ms
Protective treatment / pollution degreeTH
LC3F225V7A64 — Approvals
ParameterValue
StandardsIEC 60947-4-1 JIS C8201-4-1 EN 60947-1 IEC 60947-1 EN 60947-4-1
LC3F225V7A64 — Mechanical
ParameterValue
Width525 mm
Height110 mm
Depth235 mm

Product details

The Schneider TeSys F LC3F225V7A64 is a pre-wired star delta starter — a three-contactor assembly (KM1 star, KM2 line, KM3 delta) in one package, ready for plate mounting. It is designed for AC-3 motor starting duty: switching squirrel-cage motors during start-up and run. Rated operational current is 225 A at ≤440 V AC in AC-3 category, which means it handles the inrush and running current of motors up to that rating. Motor power capability reaches 200 kW at 380/400 V AC and 220 kW at 440 V AC. The control circuit runs on 400 V AC 50/60 Hz, with an operational voltage range of 0.85 to 1.1 Uc and a drop-out range of 0.35 to 0.55 Uc. Inrush power is 805 VA at 50 Hz and 970 VA at 60 Hz.

The 225 A rating is the continuous current the main power poles (3 x 3 NO) can carry in AC-3 duty at ≤55 °C. For a 200 kW motor at 400 V, this starter is correctly sized — the AC-3 utilisation category covers starting and plugging, not sustained overloads. The associated fuse recommendation is 315 A gG or 250 A aM at ≤440 V, which sets the short-circuit protection boundary. Rated breaking capacity is 1800 A and rated making capacity is 2250 A, both per IEC 60947-4-1. For high-duty-cycle applications (frequent starts on a conveyor or compressor), this sets the thermal and mechanical limit. The assembly includes built-in auxiliary contacts: 1 NC + 1 NO on the star contactor, 2 NC + 1 NO on the line contactor, and 1 NC + 2 NO on the delta contactor. This covers the interlocking and signalling needs for a standard star-delta sequence without adding separate aux blocks.

Mounts on a plate (not DIN rail), sized at 525 mm wide × 110 mm high × 235 mm deep. Power connections use bolted lugs or bars — M10 bolts, 185 mm² cable max, or a 32 × 4 mm busbar. Control wiring uses screw clamp terminals accepting 1 to 4 mm² flexible or solid wire, torqued to 1.2 N·m. Power circuit torque is 35 N·m. The TH protective treatment indicates tropicalisation for humid environments.

Frequently asked questions

What are the key ratings for this star delta starter?

Rated operational current is 225 A at ≤440 V AC in AC-3 category. Motor power reaches 200 kW at 380/400 V AC and 220 kW at 440 V AC. Control coil is 400 V AC 50/60 Hz. Mechanical durability is 10 Mcycles.

What standards does the LC3F225V7A64 comply with?

It complies with IEC 60947-4-1, EN 60947-4-1, JIS C8201-4-1, IEC 60947-1, and EN 60947-1. Insulation voltage is rated at 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C.

How is this starter mounted and what are the connection details?

It is plate-mounted, dimensions 525 × 110 × 235 mm. Power connections use M10 bolts accepting up to 185 mm² cable or a 32 × 4 mm busbar. Control wiring uses screw clamp terminals for 1–4 mm² wire, torqued to 1.2 N·m.

MPN
LC3F225V7A64