Schneider Electric LV846171 MasterPact MTZ2 1000A 3P Drawout

MPNLV846171
Active

Schneider Electric MasterPact MTZ2, LV846171, 3-pole drawout circuit breaker, 1000 A rated current, H2V 100 kA at 415 V AC performance class.

$3,755.97Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LV846171 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ2
RangeMasterPacT
ApplicationPower distribution protection
Control unitWithout control unit
LV846171 — Electrical ratings
ParameterValue
Rated current (In)1000 A at 40 °C
Sensor rating400 A 630 A 800 A 1000 A
Rated operational voltage (Ue)440 V AC 50/60 Hz
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)12 kV
Suitable for isolationYes conforming to EN/IEC 60947-2
LV846171 — Breaking & withstand capacity
ParameterValue
Rated ultimate breaking capacity (Icu)100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz
Rated service breaking capacity (Ics)100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz
Rated short-time withstand current (Icw)100 kA 0.5 s 100 kA 1 s 75 kA 3 s
Rated short-circuit making capacity (Icm)220 kA 220/415 V AC at 50/60 Hz 220 kA 440 V AC at 50/60 Hz
Performance typeH2V 100 kA 415 V AC
LV846171 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)15000 cycles with periodic preventive maintenance
Electrical durability (cycles)10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-2 AC-23A: 10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3
Selectivity categoryCategory B
Power dissipation150 W
LV846171 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportRails Base plate
Width441 mm
Height439 mm
Depth403 mm
Connection pitch115 mm
Upside connectionFront Rear
Downside connectionFront Rear
LV846171 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP30 conforming to EN 60529
Pollution degree3 conforming to IEC 60947-1
Operating altitude0...2000 m without derating 2000...5000 m with derating
LV846171 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H IEC 61557-12

Product details

What this breaker carries — and what that means for the line

The LV846171 is a Schneider Electric MasterPact MTZ2 drawout circuit breaker, 3-pole, rated 1000 A at 40 °C. The H2V performance class means it interrupts faults up to 100 kA at 415 V AC, which puts it in the high-breaking-capacity tier for industrial distribution where fault currents are stiff and coordination with downstream gear matters. Drawout mounting means the breaker chassis stays bolted to the switchgear, and the moving portion slides out for inspection or swap without pulling cables. That cuts downtime on a line-down event — you rack it out, slide in a spare, and get back to making clinker. The 441 mm width and 439 mm height fit standard MasterPact MTZ2 cubicle cutouts; depth is 403 mm, which you need to account for in the enclosure depth before you spec the gland plate.

Breaking capacity — the number that governs coordination

The Ics (service breaking capacity) matches at 100 kA — meaning after a fault at full rating the breaker can be reclosed and carry rated current without immediate replacement. That is Category B selectivity, so it coordinates with downstream breakers: a fault on a branch trips the branch breaker, not this main, keeping the rest of the plant live. For a cement plant where losing the main kills the kiln feed, that selectivity keeps the raw mill running while a downstream fault clears. Short-time withstand (Icw) is 100 kA for 0.5 s and 1 s, and 75 kA for 3 s. That tells you the breaker holds closed under fault current long enough for downstream devices to clear — essential for selective coordination. The making capacity (Icm) is 220 kA at 440 V AC, which covers the worst-case asymmetrical peak when closing into a bolted fault.

What the standards tell you about where it goes

Compliant with EN/IEC 60947-1 (general rules), EN/IEC 60947-2 (circuit-breakers), and Annex H for EMC. Also meets IEC 61557-12 for power metering if equipped with the optional metering module. Altitude derating starts above 2000 m — fine for most cement plants unless you are at a highland site.

Frequently asked questions

What is the breaking capacity of LV846171 at 440 V?

Both Icu and Ics are 100 kA at 440 V AC 50/60 Hz. The making capacity (Icm) is 220 kA at the same voltage.

Where can I buy LV846171 and what is the lead time?

The LV846171 is sourced to order through independent distribution. Availability and current pricing are confirmed at quote time against an RFQ — submit one for a firm lead time.

What standards does LV846171 comply with?

It complies with EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60947-2 Annex H, and IEC 61557-12. It is also certified for isolation per EN/IEC 60947-2.