Schneider Electric LV846216 — Air Circuit Breakers

LV846216 MasterPact MTZ2 3200 A Circuit Breaker, 100 kA

MPNLV846216
Active

Schneider Electric MasterPacT MasterPact MTZ2, LV846216, drawout circuit breaker, 4P, 3200 A at 40 °C, 100 kA Ics at 440 V AC, H2V performance.

$14,805.99Ref. price · indicative, final on quote
StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LV846216 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ2
RangeMasterPacT
ApplicationPower distribution protection
Control unitWithout control unit

Electrical ratings

LV846216 — Electrical ratings
ParameterValue
Rated current (In)3200 A at 40 °C
Sensor rating1600 A 2000 A 2500 A 3200 A
Rated operational voltage (Ue)440 V AC 50/60 Hz
Poles4P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)12 kV
Suitable for isolationYes conforming to EN/IEC 60947-2

Breaking & withstand capacity

LV846216 — Breaking & withstand capacity
ParameterValue
Rated ultimate breaking capacity (Icu)100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz
Rated service breaking capacity (Ics)100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz
Rated short-time withstand current (Icw)100 kA 0.5 s 100 kA 1 s 75 kA 3 s
Rated short-circuit making capacity (Icm)220 kA 220/415 V AC at 50/60 Hz 220 kA 440 V AC at 50/60 Hz
Performance typeH2V 100 kA 415 V AC

Performance

LV846216 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)15000 cycles with periodic preventive maintenance
Electrical durability (cycles)5000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-2 AC-23A: 5000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3
Selectivity categoryCategory B
Power dissipation670 W

Mechanical & connection

LV846216 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportRails Base plate
Width556 mm
Height439 mm
Depth403 mm
Neutral pole positionRight
Connection pitch115 mm
Upside connectionFront Rear
Downside connectionFront Rear

Environmental

LV846216 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP30 conforming to EN 60529
Pollution degree3 conforming to IEC 60947-1
Operating altitude0...2000 m without derating 2000...5000 m with derating

Approvals

LV846216 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H IEC 61557-12

Product details

The LV846216 is a Schneider Electric MasterPact MTZ2 drawout circuit breaker, part of the MasterPacT range. It's a 4-pole, 3200 A rated device (at 40 °C) built for power distribution protection in commercial and industrial switchboards. The H2V performance class delivers 100 kA Ics at 440 V AC — that's the service breaking capacity it can interrupt and then be reclosed without refurbishment, which matters for continuity in critical feeders.

Rated current is 3200 A at 40 °C ambient. If your switchgear room runs hotter, you'll need to derate — the operating range goes up to 70 °C, but the full 3200 A only holds at 40 °C. The Icw short-time withstand is 100 kA for 0.5 s and 1 s, and 75 kA for 3 s; that tells you the breaker can ride through a delayed trip coordination scheme without damage. Insulation voltage is 1000 V AC, impulse withstand 12 kV, so it's comfortable in 690 V systems with proper coordination, though the operational voltage here is rated at 440 V AC. Electrical durability is 5000 cycles at In under AC-23A (440 V), and 6000 cycles under AC-3. Mechanical durability is 15,000 cycles with periodic preventive maintenance. That's typical for a drawout breaker this size — it's not a daily-switching device; it's a protection and isolation device for a main or large feeder. The maximum breaking time is 25 ms, closing response 70 ms, so it clears faults fast enough for selective coordination.

This is a drawout breaker — the chassis stays wired in the switchboard, and the breaker element slides in and out for maintenance or replacement without disturbing the power connections. It mounts on rails or a base plate, with a 115 mm connection pitch. Both front and rear connections are available for upside and downside terminations, giving flexibility in busbar layout. Neutral is on the right. The IP30 rating means it's for indoor, clean environments — not washdown, not outdoor.

Frequently asked questions

What is LV846216's rated current and breaking capacity?

The LV846216 is rated 3200 A at 40 °C, with a service breaking capacity (Ics) of 100 kA at 440 V AC and a rated short-time withstand (Icw) of 100 kA for 1 s.

Where can I buy LV846216 and what is the lead time?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock or lead-time figures are published here.

What compliance standards does LV846216 meet?

The LV846216 complies with EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60947-2 Annex H, and IEC 61557-12. It is suitable for isolation per EN/IEC 60947-2.

MPN